Download Catalogue
Transcript
Index Index Pg. No. DESCRIPTION PARAMETER Operation 3 Get to Know Your Controller 4 Items Included 4 Key Introduction 5 Parameter List To set the cut-out point of the controller. 5 5 How to set other parameter. 5 To set Maximum allowable High Temperature limit. 5 P3 Parameter To set Minimum allowable low Temperature limit. 6 ROOM PROBE DIFF. To set comp. Differential (Hysterisis). 6 To set room Probe offset calibration. 6 To set time delay between comp. relay restart time. 7 P6 Parameter DRIP TIME To set drip time for defrost water to drain out. 7 P8 Parameter To set comp. relay status on room probe failure 7 CYC. ON TIME Cyclic ON time. 7 Cyclic OFF time. 8 To set door open alarm delay. 8 Evap. Fan stop coil temp. 8 8 L2 Parameter To set time delay between Evap. fan relay restart time. FAN IF COMP OFF Evap. Fan operation when compressor is off. 8 Evap. fan differential (hysteresis). 9 To set coil probe offset calibration (evap. fan coil probe). 9 L5 Parameter FAN WHEN DEFROST Evap. fan status during defrost. 9 FAN WITH DOOR L7 Parameter Evap. fan status on door open. 9 COND START DELAY To set Condenser delay to start before comp. 10 To set Condenser relay status during Hot gas defrost. 10 d2 Parameter QUICK FREEZE SP To set quick freeze set point. 10 SET POINT HIGH SET ALARM P2 Parameter LOW SET ALARM P4 Parameter ROOM PROBE CALIB P7 Parameter COMP IN PRB FAIL ON Time Parameter CYC. OFF TIME OFF Time Parameter DOOR ALARM DELEY P9 Parameter FAN STOP TEMP. L1 Parameter FAN TIME DELEY L3 Parameter COIL PROBE DIFF. L4 Parameter COIL PROBE CALIB L6 Parameter QUICK FREEZE DUR DESCRIPTION Pg. No. To set Quick Freeze time duration. 10 To set / activate power up defrost cycle. 10 To set type of defrost. 11 To set type of computation for defrost frequency. 11 E2 Parameter DEF. FREQUENCY To set Defrost frequency. 11 Ct Parameter POWER ON DEFROST E0 Parameter TYPE OF DEFROST E1 Parameter DEF. TIME CALC. E3 Parameter MAX. DEF. DURATION To set Maximum defrost duration 11-12 E4 Parameter MAX. DEF. TEMP Defrost stop temperature (Evap. coil probe). 12 Alarm to check Heater function. 12 To set display during defrost. 12 To set maximum defrost duration on coil probe fail. 12 E8 Parameter POWER ON ALM DLY Power on time delay for Alarm(HT/LT). 13 To lock keypad. 13 Revert to factory set parameters. 13 To end programming. 13 E5 Parameter HEATER CHK. FUNC P5 Parameter COMP. TIME DELAY PARAMETER E6 Parameter DISP. DURING DEF E7 Parameter PROB. FAIL DEF. DUR AL Parameter LOCK KEYPAD LP parameter RESET PARAMETERS FS Parameter END OF PROG. End Parameter Operating Messages and Icon Status. Technical Data Panel Cutout Dimensions Wiring Diagram 13-14 14 15-16 17 d1 Parameter COND WHEN DEF. CS Parameter 01 CRC1100A CRC1100A 2