Operating Instructions Measuring AC Current When measuring current, always be sure the “SEL ECTOR” switch is set to the appropriate AMP range. When in doubt, always use the highest current range first. The switch can always be reset to a lower range for a more precise reading. AC current measurements are made on the black A MP scales. Clamp the jaw the MCP9A around a single circuit wire. NOTE: Clamp only one wire at a time for measurement. If two or more wires are clamped together, the tester will not read. If the measured value on the meter scale is less than the full scale value of the next lower range, reset the “SEL ECTOR” switch to the lower range for a more accurate reading. Slide P OINTER LOCK switch toward the right to lock the pointer at its indicating point when readings must be made in a confined or difficult-toread loca t i o n . Measuring AC Voltage When measuring voltage be sure the “SEL ECTOR” switch is set to the appropriate Volt range. When in doubt, always use the highest Volt ra n g e first. The switch can always be set to a lower range for a more precise reading. AC voltage measurements are made on the red Volt scales. Insert the red and black test leads into the “COM” and “VOLT” input jacks. The test leads may be locked in position by rotating them to the right (clockwise). Connect the two test leads to the circuit under test. Measuring Resistance Maintenance Periodic Service WARNING! Repair and service of this instrument is to be performed by qualified personnel only. Improper repair or service could result in physical degradation of the meter. This could alter the protection from electrical shock and personal injury this meter provides to the operator. Perform only those maintenance tasks that you are qualified to do. These guidelines will help you attain long and reliable service from your meter: • Calibrate your meter annually to ensure it meets original performance specifications • Keep your meter dry. If it gets wet, wipe dry immediately. Liquids can degrade electronic circuits • Whenever practical, keep the meter away from dust and dirt that can cause premature wear • Although your meter is built to withstand the rigors of daily use, it can be damaged by severe impacts. Use reasonable caution when using and storing the meter Cleaning Periodically clean your meter’s case using a damp cloth. DO NOT use abrasive, flammable liquids, cleaning solvents, or strong detergents as they may damage the finish, impair safety, or affect the reliability of the structural components. Clean the input terminals as follows: WARNING! Remove all power to the circuit under test when making resistance measurements. If any voltage is present in the test circuit an erroneous reading will result and the MCP9A fuse may open. Connect the black test lead to the “COM” jack and the green test lead to the “OHMS” jack. The “OHMS” jack has an internal switch so be sure that the green test lead is inserted fully into the jack. Touch the free ends of the test leads together. The pointer will swing to the right hand side of the scale. Adjust the “OHM ADJ” control until the pointer is set on the green numeral 0. NOTE: If this adjustment cannot be made refer to the “MAINTENANCE” section. Re-zero the MCP9A each time that the tester is used for making resistance measurements. To make the resistance measurement, connect the free ends of the test leads across the element to be measured. The measured resistance value will be the green numeral indicated on the “OHMS” scale. 1. Turn the meter off and remove all test leads. 2. Shake out any dirt that may be in the terminals. 3. Soak a new swab with alcohol and work the swab around in each terminal. Battery Replacement The purpose of the internal 1.5 V, size “AA”, battery is to supply power tot he circuit under test while making resistance measurements. Eventually the battery will age to the point where it will not be possible to zero the meter with the “OHM ADJ” control. When this happens the battery should be replaced. Observe the proper battery polarity when replacing the battery. It is recommended that the battery be removed if the MCP9A is not to be used for a long period of time. Remove the screws in the rear of the case for access to the battery. WARNING! Disconnect the test leads from the circuit under test and from the meter prior to removing or installing batteries. WARNING! Under no circumstances should you expose batteries to extreme heat or fire as they may explode and cause injury. MCP9A-MAN P. 2