Transcript
INTERTEK TESTING SERVICES Applicant: ShenZhen Aoni Electronic Industry Co., Ltd. Model: BT806 Sample: 1/1 Worst Case Operating Mode: Transmit with charging Date of Test: 15 March 2013 Table 2 Radiated Emissions (2402MHz) Polarization Frequency (MHz) Reading (dBµV) Horizontal Horizontal Horizontal 2402.000 4804.000 7206.000 100.5 53.7 53.2 PreAmp Gain (dB) 36.7 36.7 36.1 Antenna Net Peak Limit Factor at 3m at 3m (dB) (dBµV/m) (dBµV/m) 28.5 35.0 37.0 92.3 52.0 54.1 114.0 74.0 74.0 Polarization Frequency Reading Pre- Antenna Average Net Average Limit (MHz) (dBµV) Amp Factor Factor at 3m at 3m Gain (dB) (-dB) (dBµV/m) (dBµV/m) (dB) Horizontal 2402.000 100.5 36.7 28.5 30.1 62.2 94.0 Horizontal 4804.000 53.7 36.7 35.0 30.1 21.9 54.0 Horizontal 7206.000 53.2 36.1 37.0 30.1 24.0 54.0 Notes: Margin (dB) -21.7 -22.0 -19.9 Margin (dB) -31.8 -32.1 -30.0 1. Peak Detector Data unless otherwise stated. 2. All measurements were made at 3 meter. Harmonic emissions not detected at the 3-meter distance were measured at 0.3-meter and an inverse proportional extrapolation was performed to compare the signal level to the 3-meter limit. No other harmonic emissions than those reported were detected at a test distance of 0.3-meter. 3. Negative value in the margin column shows emission below limit. 4. Horn antenna is used for the emission over 1000MHz. Test Engineer: Chris Chen TRF No.: FCC 15C_TX_b FCC ID: Z63-AONI80601 Report No.: 130312018SZN-001 13