Download Crouzet TEMPERATURE CONTROL USER MANUAL CTD 24
Transcript
Alarm 1 threshold (Gr.3) This parameter is available when alarm 1 is configured as process or deviation (Gr.6 – “A1.tP” = “Proc” or "dEV”) Range: - in engineering units within the span limits for process alarm; - from -1000 to 1000 digits for deviation alarm; NOTE: The span limits are configured by "ñ.ln.L" and " ñ.ln.H" configuration parameters. Low threshold used when the alarm 1 is .a band alarm (Gr.3) This parameter is available only when the alarm 1 is configured as band alarm (Gr.6 – “A1.tP” = "bAnd"). Range: from 0 to -1000 digits. High threshold used when the alarm 1 is a band alarm (Gr .3) This parameter is available only when the alarm 1 is configured as band alarm (Gr.6 – “A1.tP" = “bAnd"). Range: from 0 to 1000 digits. NOTE: The “bA1.L” and “bA1.h” values are algebraically added to the operative set point in order to obtain the band limits. Alarm 2 threshold (Gr.3) This parameter is available when alarm 2 is configured as process or deviation (Gr.6 – “A2.tP" = “Proc” or “dEV") Range: - in engineering units within the span limits for process alarm; - from -1000 to 1000 digits for deviation alarm; NOTE: The span limits are configured by "ñ.ln.L" and " ñ.ln.H" configuration parameters. 23/48