Download fx-20p-e handy programming panel operation manual
Transcript
FX-20P-E Handy programming panel Appendix A:Contents of Program Memory 2) In write to and read from file registers, the block No. should be set using a parameter. Block 0: No file register Block 1: D1000 to D1499, 500 points/500 steps Block 2: D1000 to D1999, 1,000 points/1,000 steps Block 3: D1000 to D2499, 1,500 points/1,500 steps Block 4: D1000 to D2999, 2,000 points/2,000 steps : Block 14: D1000 to D7999, 7,000 points/7,000 steps Program memory Program capacity: 2k, 4k, 8k or 16k 1) Sequence programs including K constants are identified as set values for timers and counters. 1) Sequence program (including set values of T and C) 2) File registers 3) Comments 4) Parameters The generic term "program" includes 1) to 4) above. Comments are not available in the HPP. 3) Register comments by using the A6GPP/A6PHP/Programming software on PC. Comments cannot be registered or changed in the HPP. However, when a program including registered comments is transferred to the HPP, the program is stored together with the comments to the built-in HPP RAM. 4) Parameters set the program memory capacity, the device No. range for the latch memory, the number of blocks for file registers, the number of blocks for the comment area, the entry code, the title, etc. (except the PLC model name). A-1