MobilePro-Anschalte-Installations-Handbuch_4_2_13_EN
10/19/09 16:23:19
These settings are relevant on the NT side only if a "mixed" (incoming/outgoing) B-channel assignment is
active.
The B-channels are numbered from 1 - 31.
With the fields "BchanInMin" and "BchanInMax" B-channels for incoming calls are used.
With the fields "BchanOutMin" and "BchanOutMax" B-channels for outgoing calls are used.
With the fields "BchanBiMin" and "BchanBiMax" B-channels for both directions are used.
For the assignment, the B-channels for the respective direction are used first. If no more B-channels are
available in this pool, the Bi-channels (bidirectional) are used. If none of those are available either, no
connection is possible.
Scheduling Modes (BchanInSched BchanOutSched)
Up_Count
B-channels are assigned in an order from Min to Max.
Down_Count B-channels are assigned in an order from Max to Min.
Up_Round
B-channels are used in upward sequence.
The start is not always with Min.
Down_Round
B-channels are used in downward sequence.
The start is not always with Max.