Download GuardPLC Controller Systems, User Manual
Transcript
Chapter 5 Wire the GuardPLC 2000 Controller and I/O Safety-related Analog Output Module (1755-OF8) Current Draw The 1755-OF8 module uses analog outputs to transfer analog values from the user program into outputs ranging from ±10V DC and 0…20 mA. The relationship between the value in the user program and the output value is linear and is displayed in this table. Logic Value Output Voltage Output Current 0 0.00V 0.0 mA 1000 10.00V 20.0 mA -1000 -10.00V na The GuardPLC 2000 controller features several different modules. These modules and their backplane current draw specifications are listed in this table. Cat. No. Current Draw at 3.3V DC Current Draw at 24V DC 1755-IB24XO16 0.3 A 0.5 A 1755-IF8 0.15 A 0.4 A 1755-OF8 0.15 A 0.4 A 1755-HSC 0.8 A 0.1 A 1755-L1 1.5 A 1.0 A TIP The GuardPLC 2000 controller can draw up to 30 A. The majority of this 30 A is used to source inputs and outputs. Only 1 A is required to operate the CPU module. Connect the power supply, 1755-PB720, to the 24V DC supply voltage. Refer to the GuardPLC 2000 Power Supply Installation Instructions, publication 1755-IN007, for detailed instructions. 64 Publication 1753-UM001C-EN-P - March 2010