Download User manual
Transcript
Using the system Only caretakers can reset any common alarm at a reader keypad. 24.6 Caretaker functions Some doors can be configured to allow for a temporary change of security level. The door can be set Unlocked for certain times - or set to Group code (4 digits). The command is invoked at - and applies only to – a selected door. The prerequisite is that the person doing this must belong to an access group with the Caretaker tick box selected. 24.6.1 Unlocked There are three different commands for a Caretaker to unlock the door. A18 All caretakers can then reset/lock the door. A19 Only the very same caretaker can then reset/lock the door. A20 All authorized card holders can then reset/lock the door. Proceed as follows: 1. Press A18, A19 or A20 and the yellow LED flashes three times. 2. Use the card (+ PIN). The yellow LED is lit. 3. Enter the time when the door is to be locked again. E g 1600 for 4 PM. The reader sets the door unlocked until the requested time (or a time zone change). 24.6.2 Group code Proceed as follows: 1. Press A21 and the yellow LED flashes three times. 2. Use the card (+ PIN). The yellow LED is lit. 3. Enter the time when the door is to be locked again. E g 1600 for 4 PM. 4. Enter the group code with four digits (not 0000). The yellow LED flashes once and the group code will work until the requested time (or a time zone change). Remote opening from PC will still work. 62 Building Technologies Fire Safety & Security Products 052_SiPass_Entro_6_5_A24205-A335-B318_e_en 10.03.2010