4-3-3-1. Idling motion preference
In Control map V2, you have to define an idling motion on each map as well as
Control map V1, because the idling motion is needed for the controller operation to be
started. To set an idling motion, click “Choose” button of “Idling motion” in “Registered
motion”. After clicking, opening dialog ask you to select a motion file. Select an
appropriate motion, such as a standing up motion consisting of one pose, and click
“Open”.
4-3-3-2. Cancellation
In Control map V2, the cancellation of the motion is supported as well as Control map
V1. Using cancellation, the next motion can interrupt the performing motion instead of
waiting the end of it. Using the cancellation, the operation responses of control are
improved.
Cancellations can be set as “Enable”/”Disable” on each motion registered in Control
map V2. The cancellation of “Acceptance” and “Interrupt” are supported as well as
Control map V1. In additionally, “Idling interrupt” is also supported. Thus, there are
three types of cancellations.
“Acceptance” – If this cancellation is enabled, the motion accepts another motions of
button events regardless of cancellation setting of the next motion.
“ Interrupt” – If this cancellation is enabled, the motion interrupts the another
performing motion regardless of cancellation setting of the current motion.
“Idling interrupt” – If this cancellation is enabled, the motion interrupts only the
idling motion. This type of the cancellation is used when you want to limit the situations
for the motion to be performed, such as a waking up motion started based on
accelerometers.
Although enabling cancellation improves response of the controller, it also causes an
immediate servomotor movement as well as the start of the motion and the stop of the
motion, because the cancellation of the motion causes decoupling motion. Since this
immediate movement of the servomotors consumes lots of energy, voltage supplied to
the CPU board sometimes drops. Be careful not to immediately move the servomotor. In
a worse case, the CPU board reboots because of the low voltage.
To change the setting of the cancellations, select the motion you want to change the
79