Download 5300-5600_BASIC_Reference_en-US_RevA
Transcript
STALL.JUMP parameter (integer) Purpose STALL.JUMP moves program execution to a specified line in the program when a stall occurs. Note: Refer to Section 2.6, “Stall Detection Function” for additional information. Syntax STALL.JUMP = x x = the desired line number x = 0 for no jump Range Related instructions x=0 STALL.DEADBAND — sets the maximum allowed difference in motor steps (microsteps) between encoder and pulse counts that can occur before a stall is triggered. STALL.ERROR — indicates that a stall has occurred. STALL.STOP — stops the motor when stall occurs. Programming guidelines • • Rev F Install an encoder and verify that it is set to the correct ENCODER line count. Make sure STEPSIZE is correct. (Both hardware and software) StepperBASIC Reference Manual 3 - 157