Poultry House Control
Ventilation & Curtain Level: Menu 92, Menu 95
Level
Fans,
Groups of Fans
Cycle
Time
On Off
Temp
Diff.
Var %
Curtain %
Open
1 2 3 4
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Note: The AC-2000 uses ventilation resources available to keep the set temperatures. There is no level-to-level differential drift, as there is with some leveled controllers.
For example, some ten-level controllers will drift 2.0÷F per level, or 20.0÷F from level 1 to
10. The AC-2000 maintains the target temperatures, and shifts to higher energy saving set
temperatures at precise points (System variable 4).
However, you may also set temperature differentials for each level
as desired. Use this to account for the cooling effects of air speed in tunnel
ventilation and ventilation system costs. For example, full tunnel ventilation
provides about 10÷F of cooling, calling for a 10÷F temperature differential.
Otherwise, the birds may be over cooled or over ventilated.
Rev:1.5