Download CM1000 - Belver Brasil
Transcript
Chapter 4 Measurements 4.2 SLM Measurements Select the SLM Single Channel or Scan icon. Single channels or a complete scan of all the channels can be measured. Pass/Fail Limits are used to test the measurement results, based on the location. Failing measurements are displayed in red. Locations for manual SLM and scan tests are selected by pressing the Location key (Shift F3). A pop-up window will allow the user to use the arrow keys to select a new location: Ground Block, Tap or Set-Top. 4.2.1 SLM Mode In the SLM mode the CM1000 automatically switches between analog and digital signals, based on the administrator programmed channel plan. The initial setting when the SLM mode is selected allows the user to enter channel numbers and press ENTER or use the arrow keys to sequence through the channel table. Figure 4-34 Tuning—Select channel or frequency tuning mode by pressing the F1 Ch/Freq function key to highlight the channel number or frequency. Then enter the channel or frequency on the keypad or use the arrow keys to scroll through the channels in the active Channel Table. The measurement results for each channel are displayed graphically with a numeric readout of the channel, frequency, video carrier level, audio carrier level, 2nd audio carrier level (if used), V/A (video to audio) ratio, modulation type and adjacent channel video carrier ratio. 81