Download Fire Detection Control Panel BC216-1 - honeywell
Transcript
If you have set up a fire brigade interface relay output as a transmitting device which you subsequently put out of function by selecting [Not defined], all combinations and other settings of this transmitting device will be deleted. Events occurring during authorisation level 3 are received, processed and indicated by the control panel as usual, taking into account the existing (not yet changed) parameter setup and the automatic disablement of system parts in authorisation level 3. Only for the time while new parameters are being installed (on completion of parameter setup) the control panel is not operational for approximately 5 seconds. If you perform changes on a “live” fire detection system it is possible - while the control panel operates at authorisation level 3 - that important system parts (e.g., the transmitting devices) are automatically disabled depending on the current parameter setup. During a fire alarm such system parts will not be activated! On switching back to authorisation level 1, all active alarm messages among other things will be reset during the following restart of the control panel. Do not leave the control panel in authorisation level 3 for longer than absolutely necessary for parameter setup! After completion of the parameter setup, immediately switch back to authorisation level 1 in order to re-enable the disabled system parts. You can automatically configure the works settings in the menu point [Parameter settings] - [AUTOsetup] either for the entire control panel or only for newly added hardware components of the control panel (see Chapter 2.3.12: “Automatic setup of the System configuration - [AUTO-setup]”). 2.2 Using the PC keyboard The control panel keypad is mainly designed for the user to operate the control panel. In general you can also perform the parameter setup - except for text inputs - by using the keypad. However, parameter setup is performed much easier and more comfortably by means of a standard PC keyboard connected to connector ST8 of the central processing board ZTB216-1 (see User Manual Series BC216 / Part B). It is not necessary to de-energise the control panel for connecting and disconnecting the PC keyboard. However, safely discharge static charges by touching an earth-connected metallic part beforehand. PC keyboards are produced by different manufacturers world-wide with a variety of specifications. Basically, the fire detection control panel BC216-1 should be able to process signals of all PC keyboards on the market; nevertheless, now and then it may occur that single keyboards are not entirely compatible to the fire detection control panel BC216-1. Therefore, always pay attention to the characters displayed on the LC-display when entering via a PC keyboard! 2.2.1 Function keys Special functions depending on the current authorisation level shown in the following table are assigned to the PC keyboard function keys F1, ..., F12. Key Function in authorization level 2 3 Info Info Info Silence buzzer/ Silence buzzer/ Silence buzzer/ Display test Display test Display test Info Info Parameterize function modules Info Info Parameterize fire brigade interface Info Info Parameterize detector zones Info Info Parameterize actuations Info Info Parametrize transmitting device Info Info Parameterize alarming devices 1 F1 F2 F3 F4 F5 F6 F7 F8 7