Sound Generator
18.4 Sound Generator Operations
18.4.1 To output basic cycle signal SGOF (without amplitude)
Select SGOF output by setting bit 3 (SGOB) of the sound generator control register (SGCR) to “0”.
The basic cycle signal with a frequency specified by the SGCL0 to SGCL2 and SGBR0 to SGBR3 is
output.
At the same time, the amplitude signal with an amplitude specified by the SGAM0 to SGAM6 is output
from the SGOA pin.
Figure 18-6:
Sound Generator Output Operation Timing
n
n
n
n
n
n
Timer
Comparator 1
coincidence
SGOF
SGOA
User’s Manual U12670EE3V0UD00