Viewing Device Variables and Diagnostics Transducer Block This section contains information on the DVC6000f digital valve controller transducer block. Descriptions of all transducer block parameters are included. The transducer block decouples function blocks from the local output functions required to command output hardware. The transducer block typically contains setup and calibration information. Processor Impaired Program Memory Alert—This alert is active if a pending flash or NVM failure is present. Static Memory Alert—This alert is active when there is a failure of the FRAM memory where static parameters are stored. Processor Alert—This alert is active when there is a failure of the main processor. I/O Processor Alert—This alert is active when there is a failure of the I/O processor. Configuration—If a configuration alert is active it will appear under CONFIG ALERTS Device Diagnostics Active PlantWeb Alerts Output Block Timeout Output Block Timeout Alert—This alert is active if the output block has not executed for a period of time longer than the configured timeout. (TB > Device Diagnostic > Active PlantWeb Alerts) To view the active PlantWeb alerts select Active PlantWeb Alerts. Blocks Set to Default Blocks Set to Default Alert—This alert is active if the resource block has undergone Restart with Defaults. This will stay active until the transducer block is changed from Out of Service. Alert Conditions Sensor—If a configuration alert is active it will appear under SENSOR ALERTS (TB > Device Diagnostics > Alert Conditions) Instrument Alert Conditions, when enabled, detect many operational and performance issues that may be of interest. The alert conditions for each group of alerts are listed below. If there are no alerts active for a particular group the group will not be displayed on the Field Communicator. Electronics—if an electronics alert is active it will appear under ELECT ALERTS Drive Current Drive Current Alert—This alert is active when the difference between the expected Drive Current and the actual Drive Current has exceeded the Drive Current Alert Time. Drive Signal Drive Signal Alert—The Drive Signal Alert is active if one of the following conditions exist: Where Zero Power Condition is defined as closed: Drive Signal < 10% and Calibrated Travel > 3% Drive Signal > 90% and Calibrated Travel < 97% Where Zero Power Condition is defined as open: Drive Signal < 10% and Calibrated Travel < 97% Drive Signal > 90% and Calibrated Travel > 3% December 2009 Travel Sensor Travel Sensor—This alert is active if the Travel Sensor reading is outside the functional range. Pressure Sensors Pressure A Sensor Alert—This alert is active if the Port A Pressure Sensor reading is outside the functional range. Pressure B Sensor Alert—This alert is active if the Port B Pressure Sensor reading is outside the functional range. Supply Pressure Sensor Alert—This alert is active if the Pressure Sensor reading is outside the functional range. Pressure Fallback Pressure Fallback Alert—This alert is active if a travel sensor failure or a gross travel deviation has resulted in fallback to pressure control. Temperature Sensor Temperature Sensor Alert—This alert is active if the temperature sensor reading is outside the functional range of the sensor. Environment—If an environment alert is active it will appear under ENVIRO ALERTS Supply Pressure Supply Pressure Hi Alert—This alert is active if the supply pressure exceeds the Supply Pressure Hi Alert. 6-7 6