Using PlantWeb Alerts Table C-3. Using PlantWeb Alerts (Continued) PlantWeb Alert (Group) (Default Alert Category Travel Sensor (Sensors) (Failed) Alert Condition and (Default)) Travel Sensor (Enabled) What the Alert is Detecting The travel feedback is within acceptable limits. Effect on Valve / Instrument Recommended Action If configured for Self Test Shutdown, then the transducer “Actual” mode is placed Out of Service until the problem is fixed. Out of service results in the actuator being at the Zero Power Condition. Check mounting and linkage Help Travel feedback value is outside expected limits. If this problem occurs during instrument set-up, the most likely cause is faulty mounting or improper adjustment of the travel sensor. If this problem occurs during normal operation, the most likely cause is a failure of the travel sensor or damaged linkage. To correct, 1) Insure proper mounting and linkage adjustment. 2) Inspect and test travel sensor 3) Toggle the transducer target mode. If the problem persists, replace the printed wiring board (PWB) assembly. Output Press Sensor (Sensors) (Maintenance) Port A Pressure Sensor (Enabled) The pressure sensor reading is outside the functional range of the sensor. Port B Pressure Sensor (Enabled) Supply Press Sensor (Sensors) (Advisory) Supply Press Sensor (Enabled) If configured for Self Test Shutdown, then the transducer “Actual” mode is placed Out of Service until the problem is fixed. Out of service results in the actuator being at the “No Power” condition. Confirm proper air supply If it is verified that the air supply is ok, replace the printed wiring board (PWB) assembly. None − Indicates a possible hardware problem that would degrade diagnostic capability. The pressure sensor reading is outside the functional range of the sensor. None − Indicates a possible hardware problem that would degrade diagnostic capability. The pressure sensor on-board the device has failed. This may be due to excessive supply pressure or contaminated air. Confirm proper air supply The pressure sensor on-board the device has failed. This may be due to excessive supply pressure or contaminated air. If it is verified that the air supply is ok, replace the printed wiring board (PWB) assembly. Temperature Sensor (Sensors) (Advisory) Temperature Sensor (Enabled) The temperature sensor reading is outside the functional range of the sensor. None − Indicates a possible hardware problem that would degrade instrument calibration and diagnostic capability. Replace PWB assembly. The temperature sensor on-board the device has failed or the unit has been exposed to an temperature extreme beyond the recommended limits. −Continued− December 2009 C-9 C