Download DVC6000f Digital Valve Controllers
Transcript
Transducer Block (TB) Menu Structure (Continued) PARAMETER LABEL MENU STRUCTURE I/O Processor Man Recovery TB > Configure/Setup > Detailed Setup > Alerts > Elect Alerts > Processor Impaired > Shutdown Recovery.I/O Processor Man Recovery I/O Processor Shutdown TB > Configure/Setup > Detailed Setup > Alerts > Elect Alerts > Processor Impaired > Shutdown Trigger.I/O Processor Shutdown Inlet Pressure TB > Configure/Setup > Detailed Setup > Valve and Actuator > Valve > Inlet Pressure Input Characterization TB > Configure/Setup > Detailed Setup > Response Control > Input Characterization TB > Device Variables > Input Characterization Integrator Limited Hi TB > Device Diagnostics > Status > Self Test Status > Self Test Status.Integrator Limited Hi Integrator Limited Lo TB > Device Diagnostics > Status > Self Test Status > Self Test Status.Integrator Limited Lo Integrator Suspended TB > Device Diagnostics > Status > Self Test Status > Self Test Status.Integrator Suspended IOP Failure TB > Device Diagnostics > Status > Self Test Status > Self Test Status.IOP Failure Last Calibration Type TB > Configure/Setup > Detailed Setup > Instrument > Last Calibration Type Leak Class TB > Configure/Setup > Detailed Setup > Valve and Actuator > Trim > Leak Class Length Units TB > Configure/Setup > Detailed Setup > Instrument > Length Units Lever Arm Length TB > Configure/Setup > Detailed Setup > Valve and Actuator > Actuator > Lever Arm Length Lever Style TB > Configure/Setup > Detailed Setup > Valve and Actuator > Actuator > Lever Style Lost Static Data TB > Device Diagnostics > Status > Block Error > Block Error.Lost Static Data Lower Bench Set TB > Configure/Setup > Detailed Setup > Valve and Actuator > Actuator > Lower Bench Set MAI Channel 1 TB > Configure/Setup > Detailed Setup > MAI Channel Map > MAI Channel 1 MAI Channel 2 TB > Configure/Setup > Detailed Setup > MAI Channel Map > MAI Channel 2 MAI Channel 3 TB > Configure/Setup > Detailed Setup > MAI Channel Map > MAI Channel 3 MAI Channel 4 TB > Configure/Setup > Detailed Setup > MAI Channel Map > MAI Channel 4 MAI Channel 5 TB > Configure/Setup > Detailed Setup > MAI Channel Map > MAI Channel 5 MAI Channel 6 TB > Configure/Setup > Detailed Setup > MAI Channel Map > MAI Channel 6 MAI Channel 7 TB > Configure/Setup > Detailed Setup > MAI Channel Map > MAI Channel 7 MAI Channel 8 TB > Configure/Setup > Detailed Setup > MAI Channel Map > MAI Channel 8 Maint Active TB > Configure/Setup > Detailed Setup > Alert Handling > Simulate Active Alerts > Maint Active Maintenance Enable TB > Configure/Setup > Detailed Setup > Alerts > PlantWeb Alert Enable > Maintenance Enable Maintenance Suppress TB > Configure/Setup > Detailed Setup > Alerts > PlantWeb Alert Reporting > Maintenance Suppress Maximum Recorded Supply Pressure TB > Device Diagnostics > Device Record > Maximum Recorded Supply Pressure Maximum Recorded Supply Pressure Time TB > Device Diagnostics > Device Record > Maximum Recorded Supply Pressure Time Maximum Recorded Temperature TB > Device Diagnostics > Device Record > Maximum Recorded Temperature Maximum Recorded Temperature Time TB > Device Diagnostics > Device Record > Maximum Recorded Temperature Time Maximum Supply Pressure TB > Configure/Setup > Detailed Setup > Instrument > Maximum Supply Pressure Minimum Recorded Supply Pressure TB > Device Diagnostics > Device Record > Minimum Recorded Supply Pressure Minimum Recorded Supply Pressure Time TB > Device Diagnostics > Device Record > Minimum Recorded Supply Pressure Time Minimum Recorded Temperature TB > Device Diagnostics > Device Record > Minimum Recorded Temperature Minimum Recorded Temperature Time TB > Device Diagnostics > Device Record > Minimum Recorded Temperature Time MLFB Error TB > Device Diagnostics > Status > Self Test Status > Self Test Status.MLFB Error Nominal Supply Pressure TB > Configure/Setup > Detailed Setup > Valve and Actuator > Actuator > Nominal Supply Pressure Out of Service TB > Device Diagnostics > Status > Block Error > Block Error.Out of Service Outlet Pressure TB > Configure/Setup > Detailed Setup > Valve and Actuator > Valve > Outlet Pressure Outblock Selection TB > Configure/Setup > Detailed Setup > Response Control > Outblock Selection Output Block Timeout TB > Configure/Setup > Detailed Setup > Alerts > Configuration Alerts > Output Block Timeout Output Block Timeout Alert TB > Configure/Setup > Detailed Setup > Alerts > Configuration Alerts > Output Block Timeout > Elect Active.Output Block Timeout Alert Output Block Timeout Alert Enable TB > Configure/Setup > Detailed Setup > Alerts > Configuration Alerts > Output Block Timeout > Elect Active.Output Block Timeout Alert Enable Output Block Timeout Manual Recovery TB > Configure/Setup > Detailed Setup > Alerts > Configuration Alerts > Output Block Timeout > Shutdown Recovery.Output Block Timeout Manual Recovery −Continued− iv iv