Download ADPRO PRO E-PIR System Setup Manual

Transcript
ADPRO® PRO
Passive-Infrared Perimeter
Intrusion Detection Systems
(PIR PIDS)
System Setup Manual
December 2014
Document: 26571_03
ADPRO PRO E by Xtralis
System Setup Manual
Intellectual Property and Copyright
This document includes registered and unregistered trademarks. All trademarks displayed are the trademarks of
their respective owners. Your use of this document does not constitute or create a licence or any other right to use
the name and/or trademark and/or label.
This document is subject to copyright owned by Xtralis AG (“Xtralis”). You agree not to copy, communicate to the
public, adapt, distribute, transfer, sell, modify or publish any contents of this document without the express prior
written consent of Xtralis.
Disclaimer
The contents of this document is provided on an “as is” basis. No representation or warranty (either express or
implied) is made as to the completeness, accuracy or reliability of the contents of this document. The manufacturer
reserves the right to change designs or specifications without obligation and without further notice. Except as
otherwise provided, all warranties, express or implied, including without limitation any implied warranties of
merchantability and fitness for a particular purpose are expressly excluded.
General Warning
This product must only be installed, configured and used strictly in accordance with the General Terms and
Conditions, User Manual and product documents available from Xtralis. All proper health and safety precautions
must be taken during the installation, commissioning and maintenance of the product. The system should not be
connected to a power source until all the components have been installed. Proper safety precautions must be taken
during tests and maintenance of the products when these are still connected to the power source. Failure to do so
or tampering with the electronics inside the products can result in an electric shock causing injury or death and may
cause equipment damage. Xtralis is not responsible and cannot be held accountable for any liability that may arise
due to improper use of the equipment and/or failure to take proper precautions. Only persons trained through an
Xtralis accredited training course can install, test and maintain the system.
Liability
You agree to install, configure and use the products strictly in accordance with the User Manual and product
documents available from Xtralis.
Xtralis is not liable to you or any other person for incidental, indirect, or consequential loss, expense or damages of
any kind including without limitation, loss of business, loss of profits or loss of data arising out of your use of the
products. Without limiting this general disclaimer the following specific warnings and disclaimers also apply:
Fitness for Purpose
You agree that you have been provided with a reasonable opportunity to appraise the products and have made
your own independent assessment of the fitness or suitability of the products for your purpose. You acknowledge
that you have not relied on any oral or written information, representation or advice given by or on behalf of Xtralis
or its representatives.
Total Liability
To the fullest extent permitted by law that any limitation or exclusion cannot apply, the total liability of Xtralis in
relation to the products is limited to:
i. in the case of services, the cost of having the services supplied again; or
ii. in the case of goods, the lowest cost of replacing the goods, acquiring equivalent goods or having the goods
repaired.
Indemnification
You agree to fully indemnify and hold Xtralis harmless for any claim, cost, demand or damage (including legal costs
on a full indemnity basis) incurred or which may be incurred arising from your use of the products.
Miscellaneous
If any provision outlined above is found to be invalid or unenforceable by a court of law, such invalidity or
unenforceability will not affect the remainder which will continue in full force and effect. All rights not expressly
granted are reserved.
26571_03
i
System Setup Manual
ADPRO PRO E by Xtralis
Document Conventions
The following typographic conventions are used in this document:
Convention Description
Bold
Used to denote: emphasis
Used for names of menus, menu options, toolbar buttons
Italics
Used to denote: references to other parts of this document or other
documents. Used for the result of an action.
The following abbreviations are used in this document.
Abbreviation Description
AA
Aperture Angle
CZ
Creep Zone
DR
Detection Rate
ESD
Electrostatic Sensitive Device
FAR
False Alarm Rate
GND
Ground
QSG
Quick Setup Guide
PID
Perimeter Intrusion Detector
PIDS
Perimeter Intrusion Detection System
PIR
Passive-Infrared
The following icons are used in this document:
Convention
Description
Caution: This icon is used to indicate that there is a danger to
equipment. The danger could be loss of data, physical damage, or
permanent corruption of configuration details.
Warning: This icon is used to indicate that there is a danger of electric
shock. This may lead to death or permanent injury.
Warning: This icon is used to indicate that there is a danger of inhaling
dangerous substances. This may lead to death or permanent injury.
Danger! This icon is used to indicate that there is a danger of falling
down! There is acute danger, when working with unsecured ladders.
Unsecured ladders can slip and cause a fall that can lead to serious
injuries. Additional information: refer to local „Safety at Work Act“.
Note! This icon is used to highlight useful advice and
recommendations as well as information for an efficient and troublefree operation.
ii
26571_03
ADPRO PRO E by Xtralis
System Setup Manual
Contact Us
UK and Europe
+44 1442 242 330
D-A-CH
+49 431 23284 1
The Americas
+1 781 740 2223
Middle East
+962 6 588 5622
Asia
+86 21 5240 0077
Australia and New Zealand
+61 3 9936 7000
www.xtralis.com
26571_03
iii
System Setup Manual
ADPRO PRO E by Xtralis
This page is intentionally left blank.
iv
26571_03
ADPRO PRO E by Xtralis
System Setup Manual
Table of Contents
1
PRO E-Tool Software
1.1
1.2
1.3
2
3
3
13
35
iCommission
37
2.1
2.2
2.3
37
38
39
Front User Panel Overview
iOS App Overview
iCommission Installation and Alignment
PRO E-IPM (IP Module)
43
3.1
3.2
3.3
43
44
51
Notes
26571_03
Software Installation
Use of ADPRO PRO E-Tool Software
Uninstall Software
3
System Overview
xPico Module Setup (PRO (E) Series Detector)
PC Setup (com0com with com2tcp)
54
1
System Setup Manual
ADPRO PRO E by Xtralis
This page is intentionally left blank.
2
26571_03
ADPRO PRO E by Xtralis
1
System Setup Manual
PRO E-Tool Software
1.1
Software Installation
The ADPRO ® PRO E-Tool for Windows® (XP, Win 7, Win 8) is available for download through
www.xtralissecurity.com. It connects to PRO/PRO E-detectors through RS-232/USB/IP (through bus
converters or virtual COM ports) and is used for setting up detectors during commissioning , optimizing the
settings and monitoring detectors in use. It can be used for all types of detectors.
The Software shows all current operation parameters and real time sensor signals of the selected detector.
This is useful in various situations, such as realignment of the detector, adapting certain parameters or
blanking out objects in the detection area causing unwanted alarms.
The ADPRO PRO E-Tool for Windows® installation wizard allows you to easily install the Software by
providing you with direct and easy-to-follow steps whether installation is made on an XP or Windows 7/8
platform.
This section discusses how to install the Software on Windows 7/8 and XP platforms, in addition to
configuring the communication port.
26571_03
3
System Setup Manual
1.1.1
ADPRO PRO E by Xtralis
Installation on Windows 7/8
To install the Software on a Windows 7/8 platform, do the following:
1.
2.
3.
4.
5.
Unzip the file “Setup_PROXX.zip”,
Rename the file “Setup_PROXX.txt” to “Setup PROXX.exe”,
Double click the file “Setup PROXX.exe”, a security warning window appears,
Click “Run”, a user account control window appears,
Click “Yes”, the ADPRO PRO E-Tool setup installation wizard starts and the following window appears:
If you want to cancel the installation process, click “Cancel”, the following message appears:
Click “Yes” to cancel the installation process, or “No” to resume it. You can reinstall the software later.
6. Click “Next”, the following window appears:
You can save the ADPRO PRO E-Tool for Windows® in the selected folder or specify another one by
clicking “Browse” then selecting it.
7. Click “Next”, the following window appears:
4
26571_03
ADPRO PRO E by Xtralis
System Setup Manual
The window shows where the software’s shortcuts will be created, if you want to specify another folder,
click “Browse…” and select it.
You can return to the previous window to make the changes you want by clicking “Back”. This button is
available in all windows.
8. Click “Next”, the following window appears:
The window shows the destination location and start menu folder you specified.
9. Click “Install”, the following window appears:
26571_03
5
System Setup Manual
ADPRO PRO E by Xtralis
10. Wait till the installation is complete, the following window appears:
11. Click “Finish”.
6
26571_03
ADPRO PRO E by Xtralis
1.1.2
System Setup Manual
Installation on XP
To install the Software on an XP platform, follow these steps:
1. Unzip the file “Setup_PROXX.zip”,
2. Rename the file “Setup_PROXX.txt” to “Setup PROXX.exe”,
3. Double click the file “Setup PROXX.exe”,the ADPRO PRO E-Tool Software setup wizard starts and the
following window appears:
4. Click “Next”, the following window appears:
You can save the ADPRO PRO E-Tool for Windows® in the selected folder or specify another one by
clicking “Browse” then selecting it.
26571_03
7
System Setup Manual
ADPRO PRO E by Xtralis
5. Click “Next”, the following window appears:
The window shows where the Software’s shortcuts will be created, if you want to specify another folder,
click “Browse” and select it.
6. Click “Next”, the following window appears:
The window shows the destination location and start menu folder you specified.
7. Click “Install”, the following window appears:
8. Wait till the installation is complete, the following window appears:
8
26571_03
ADPRO PRO E by Xtralis
System Setup Manual
9. Click “Finish”.
The ADPRO PRO E-Tool for Windows® is now installed in your computer in the specified directory and the
following structure is created:
Each sub-folder is responsible for a specification action as follows:
Contains all images taken using the Software.
Contains all detector configuration files.
Contains all statistics and debugger files.
Contains all detectors definition files. Each detector model requires its specific INI file.
Contains specific data relevant to the display structure such as logo on images, etc. This
file must not be deleted.
Installation program for setup and signal display.
26571_03
9
System Setup Manual
1.1.3
ADPRO PRO E by Xtralis
Configuration of Communication Port
It is important to configure the communication port that will be dedicated to the Software before you start using
it.
If you are using a Windows 7/8 platform, follow these steps to configure the port:
1.
2.
3.
4.
5.
Connect the “IFM-485-ST” to the available port,
Right click “My Computer”,
Click “Manage”,
Click “Device Manager”,
Click “Ports (COM and LPT)”, a list of available ports appears as shown below:
6. Right click “USB Serial Port (COM3)” to update its driver software,
7. Click “Update Driver Software…”, the following window appears:
8. Select “Search automatically for updated driver software”, the following window appears:
9. Wait for the search to complete, the following window appears:
10
26571_03
ADPRO PRO E by Xtralis
System Setup Manual
10. Click “Close”.
If you are using an XP platform, follow these steps to configure the communication port:
1.
2.
3.
4.
5.
Right click “My Computer”,
Click “Manage”,
Click “Device Manager”,
Click “Ports (COM and LPT)”,
Right click “Communications Port (COM1)”, the following menu appears:
6. Click “Update Driver…”, the following window apppears:
7. Select “Install the software automatically (Recommended)”,
8. Click “Next”, the following window appears:
26571_03
11
System Setup Manual
ADPRO PRO E by Xtralis
9. Wait while the wizard searches for the update, the following window appears:
10. Click “Finish”.
Notes:
l
l
l
If your computer features a RS232 data bus, you can directly connect it to the IFM-485-ST via COM1 or
COM2 without any additional drivers.
Every time you change the communication port you are using, you need to reconfigure its driver software.
Port number varies depending on the system you are using.
For more information on how to associate the communication port with the Software, refer to "Select
Communication Port).
12
26571_03
ADPRO PRO E by Xtralis
1.2
System Setup Manual
Use of ADPRO PRO E-Tool Software
As mentioned earlier, the Software helps you to optimize the settings and monitor the detector(s) in use. After
you have successfully mounted the detector and configured the settings you need, you can start using the
Software.
Once installed, a shortcut for PRO 9.x is created and can be accessed through the applications menu, it
appears as follows:
The ADPRO PRO E-Tool for Windows® provides various tools and features that allow you to control and
monitor the detectors and maximize their benefit. They are categorized into menus for easier access.
In addition, you can access any tool or feature through the buttons that appear in the toolbar as follows:
Symbol
Action
Open Detector INI (legacy feature, please do not use)
Search Detector
Up/download settings
Debugger
Statistics
Scope
View picture
Run
Stop
Take picture
As a general preference you can set the language and audible alarm indication.
Language Selection
The Software provides the settings and parameters in various languages displayed in this menu.
To switch between the available languages, follow these steps:
1. Click “Options”, then “Language”,
2. Select the language you want.
26571_03
13
System Setup Manual
ADPRO PRO E by Xtralis
Parameters and settings are now displayed in the selected language, but as for the interface language itself it
is only available in English.
Audio ouput; Beep
Click “Options”, then “Beep”
If this option is checked, whenever the detector detects something, you’ll hear a beep.
Moreover, the Software provides shortcuts through the keyboard for faster access to the required tool, as
follows:
Shortcut
Action
<F1>
About the Software
<F2>
Open detector definition file window.
<F3>
Search for a detector.
<F4>
Up/Download
<Ctrl> + B
Beep
<F5>
Run scope
<Ctrl> + <F5>
Stop scope
<F6>
Change scroll direction, “right to left” or “left to right”
<F7>
Hide/ show grid
<F8>
Increase signal speed
<Ctrl> + <F8>
Decrease signal speed
<F9>
Clear scope
<F10>
Delete all triggers
<Ctrl> + <K>
Open scope window
<Ctrl> + <P>
Take picture
<Ctrl> + <V>
View picture
<Ctrl> + <A>
Picture auto
<Ctrl> + <O>
Picture memo
<Ctrl> + <M>
Open statistics window
<Ctrl> + <T>
Test
<Ctrl> + <D>
Open debugger window
The following sections discuss all the actions you can perform, the available tools and how to use them.
14
26571_03
ADPRO PRO E by Xtralis
1.2.1
Connect to Detectors
1.2.1.1
File
System Setup Manual
Please note: This is a legacy feature, do not use it during normal operation.
This option allows you to select the detector type to be expected by the software by preloading the respective
INI file. If this selected type does not match the connected detector there will be this kind of error message:
If you do not load any INI-File before selecting a detector, the software will automatically select the correct
INI-File for you. If the error message above appears anyway, you’re software is not compatible with the
detector, please connect our tech support for a software update.
1.2.1.2
Select Communication Port
First select the communication port which is connected to the RS-485:
1. Click “Option”,
2. Click “Com Port”, a menu listing the available ports appears,
3. Select the port you want; it will be marked with a (
Note:
1.2.1.3
) sign.
Communication ports’ numbers vary according to the system you are using and available ports.
Select detector
Before you start using the ADPRO PRO E-Tool for Windows®, you need to select the detector to be used.
The Software normally finds the detector’s definition file automatically. This step is only required if there is no
automatic loading of the detector.
There are two methods for selecting the detector in use in order to load its definition file and connect it to the
RS-485 bus.
1. Click “Option”,
2. Click “Search Detector”,
3. Click “Start”, or press keys <ALT> + <S>, a list of found detectors appears as shown below:
Note:
26571_03
Detectors are given IDs (addresses) in the range of 1 to 254. It is recommended to narrow down the
range when searching for a detector so as not to take time and retrieve the connected detectors
more quickly.
Each detector must have a unique address. If more than one detector is given the same address
15
System Setup Manual
ADPRO PRO E by Xtralis
and is connected to the same bus, none of them will appear on the Software.
To resolve this problem, disconnect all detectors and configure each one separately. This will
ensure that no detector uses the same ID of another one.
The number on the left of the “>” sign is the detector’s ID. The type of the detector and the firmware
version number are on the right of the “>” sign.
You can stop the search process by pressing <ALT> + <S> or clicking “Stop”.
To close the search window, click “ESC”.
If no detectors are found, the following message appears:
Make sure you’ve selected the correct COM port (in which case the TX LED of the bus interface module
should be blinking during the search and the RX LED should be blinking if a detector is found) and that the
search range covers the detectors’ addresses. Click “OK”, check for errors, and repeat the search.
4. Select the detector you wish to use, or enter its address in “Choice” field,
5. Click “OK”.
1.2.2
Up/Download Settings
The Software simplifies the process of detector configuration and allows you to save time spent in setting
other detectors values. You can configure a detector and use the same settings for other detectors of the
same type connected to the Software.
You can manage setting options, upload a detector’s settings, download them from a definition file, and save
them to a new definition file, etc.
The Up/Download window has the following functions:
Content and layout are detector-model-dependent and primarily designed to review and change the detector’s
parameters. These include address, sensitivity, output functions, etc.
16
26571_03
ADPRO PRO E by Xtralis
System Setup Manual
It also shows the actions you can perform where each one is represented with a certain button as follows:
Symbol
Action
Upload settings to detector
Download detector’s settings
Copy
Insert
Save to configuration file
Load from configuration file
Also, the above actions can be accessed by clicking “Setting”, the following menu appears:
The following sections discuss all the actions you can perform, the available tools and how to use them.
Note:
Setting options depend on detector model. Displayed positions and displayed terms of option may
vary depending on detector model.
To select a detector to load its settings, you can:
l
Select the detector from the drop-down menu then click (
l
Press <F3> and search for it by following the same steps mentioned in (Select detector), then click (
To close the Setting window after making, click (
Note:
).
).
).
If you attempt to close the Settings window before saving the changes you make, the following
message appears:
If you are sure you want to exit the window without saving, click “Yes”; otherwise, click “No” then
save the changes you made.
Upload Settings
To upload settings to detector, follow these steps:
1. Make the changes you want to the fields you can change,
2. Click (
Note:
26571_03
). Successful upload is represented with (
Make sure to click (
).
) to save the changes you made; otherwise, they are lost.
17
System Setup Manual
ADPRO PRO E by Xtralis
Factory Settings
You can reinstate the factory default configuration to the detector instead of the changes you made in the
following cases:
l
l
The detector does not seem to work properly.
A previous version of the ADPRO PRO E-Tool for Windows® was used on the same detector.
To display and use the factory default settings, follow these steps:
1. Click “Factory”, the following message appears:
2. Click “Yes” to replace the values with the factory ones,
3. Click (
) to save them in the detector’s configuration file.
Download Settings
To download the detector’s settings, follow these steps:
1. Make the changes you want,
2. Select the detector,
3. Click (
).
The configuration status is represented with the following symbols:
Uploading configuration
Changed configuration
Communication problem
Downloading configuration
Copy Settings
To copy the settings of a detector and use them in another one, follow these steps:
1. Select the detector which settings you want to copy,
2. Click (
),
3. Select the detector to which you want to apply the copied settings,
4. Click (
),
5. Save Settings to CFG File.
To save the configuration in the “CFG” sub-folder accessed through the ADPRO PRO E-Tool for Windows®
folder saved in the computer, follow these steps:
1. Make the changes you want,
2. Click (
18
), the following field appears:
26571_03
ADPRO PRO E by Xtralis
System Setup Manual
3. Enter file name,
4. Click “OK” to save, or “Abort” to cancel the action.
Load Settings from CFG File
To load the configuration saved in a CFG file, follow these steps:
1. Click (
), the following window appears:
2. Select the file,
3. Click “Open”, the configuration appears in the Settings window so you can make sure you are using the
desired configuration.
4. Click (
1.2.2.1
) to upload settings to detector.
Setting Options for PRO E and PRO E-RF Detectors
The Setting window displays the setting options for the selected detector where each field represents a
certain value as follows (e.g. PRO E-100H).
26571_03
19
System Setup Manual
ADPRO PRO E by Xtralis
List of settings for PRO E-detectors
Choice
Selectable list of all detectors connected to the same bus (i.e. COM port), which
allows for convenient copy/paste-ing of common settings between the detectors.
Address
1-255
Set detector’s identification bus address (1-255, default 1).
Note:
ATD
ON
Enables “Adaptive Threshold Determination”.
OFF
Disables “Adaptive Threshold Determination”.
Note:
Out x1
Make sure that each and every detector has an individual
address from 1-255 before connecting them to a common
bus.
Disable ATD function prior to walking test to optimize
performance of detector.
ON
Enables respective output relay.
OFF
Disables respective output relay.
Delay Out x1
OFF
adds a turn-off delay in ms, from 1/10s (100ms) to 1min (60000ms),
(default 2500).
Sensitivity
CZ/Zone x/Main
0.5-1.
Sets sensor sensitivity in creep zone (360PROtect) / in the main IR
detector zone or in the different zones 1-3 or 1-6, (depending on
number of available channels) from 50% (0.5) to 150% (1.5), (default
1.0).
Out x inverse3
OFF
Relay opens upon alarm, normally closed (default off).
ON
Relay closes upon alarm, normally open.
OFF
Disables legacy mode (default off).
ON
Enables legacy mode, which allows alarm management with PRO
detector protocol without the PRO E enhancements. This means, that
new events, like 360PROtect alarm and anti-masking alarm are
assigned to existing events.
ON
Enables the 360PROtect sensor (default on).
OFF
Disables the 360PROtect sensor.
Legacy mode
CZ coverage
20
26571_03
ADPRO PRO E by Xtralis
Pulse count2
System Setup Manual
0 - 10
Number of additional pulses (0 – 10) before an alarm is generated.
OFF
Triggers alarm on first pulse.
Reset alarm
counter
Select “on” to resets internal alarm counter.
Reset Vandal
position
Select “on” to write new alignment position into non-volatile RAM as
baseline for tamper protection in case of incorrect alignment of the
detector.
Reset anti masking
Select “on” to writes new anti masking sensor reading into non-volatile
RAM as baseline for masking protection in case of masking the front
of the detector.
1 Standard PRO E-detectors
have 3 outputs, while H-versions have 5 and PRO E-RF detectors have 1, thus
each output related setting (activation, delay, reversal) occurs once, 3 or 5 times respectively.
2 Only
for volumetric detectors, curtain detectors have no pulse count feature.
3 Does
not apply to PRO E-RF detectors.
1.2.2.2
Setting Options for PRO Detectors
This software is also fully compatible with all PRO detectors which have the following settings: (screenshot
example shows a PRO-45DH in hardware configuration mode).
Note:
Several of the PRO detector settings have the prefix “SW”. This indicates, that they can be set here
in software, but also in hardware through DIP switches.
If the detector is set to software installation mode (DIP 1 and 2 both “ON”) these settings can be
adjusted using this tool, if the detector is in hardware mode (DIP 1 and 2 in any other combination)
those settings are greyed out and are controlled by DIP switch settings. See details in PRO
detector manual “ADPRO PRO-Series EN, document no. (20780)”.
List of settings for PRO detectors
Choice
Selectable list of all detectors connected to the same bus (i.e. COM port), which
allows for convenient copying / pasting of common settings between the detectors.
Address
1-255
Set detector’s identification bus address (1-255, default 1).
Note:
Configuration
HW / SW
Displays current operation mode: Hardware or Software.
Note:
26571_03
Make sure that each and every detector has an
individual address from 1-255 before connecting them
to a common bus.
Operation modes can only set by DIP-switches 1 and 2
on connector board of detector.
21
System Setup Manual
Channel L/M/S 1)
Output function
[Relay | Transistor]
ADPRO PRO E by Xtralis
ON
Long, medium and short range channels may be enabled
individually by selecting “ON” from drop-down menu.
OFF
Long, medium and short range channels may be disabled
individually by selecting “OFF” from drop-down menu.
If relay function is set to “ON”, the following two options are available in the dropdown menu:
1. “IR + VAN | IR + VAN”: Using relay and transistor open collector to signal
intrusion alarms and tamper alarms.
2. “IR + VAN”: Using only relay to signal intrusion alarms and using only
transistor open collector to signal tamper alarms. This allows identifying
alarms.
Output [OC1 | OC2] 5) This feature is only available with intrinsically safe detectors.
These detectors have two open collector outputs, which have to be connected via
the recommended ex-barriers and through which two relay outputs can be used.
The following options can be accessed via a drop-down menu:
1. “IR | VAN”:
This serves to issue intrusion alarms on relay 1 and vandalism alarms on relay
2 at the ex-barrier, which serves to clearly distinguish the alarms. This is the
factory setting.
2. “IR + VAN | IR + VAN”:
This setting is used to issue both alarms at the same time for intrusion and
vandalism on relays 1 and 2 at the ex-barrier. Therefore it is not possible to
distinguish the alarms.
Relay function
OFF
Disables output function of relay.
ON
Enables output function of relay.
Normal
Relay opens when in alarm.
Inverted
Relay closes when in alarm.
Transistor output
logic
Normal
OC opens when in alarm.
Inverted
OC closes when in alarm.
Channel right/left 2)
ON/ OFF Enables/ Disables right/ left channel.
Relay output logic
List of settings for PRO detectors
SW sensitivity
right/left [%] 2)
Modifies sensitivity of right/left channel within bandwidth 20 % - 140%.
SW range 4)
Detection range can be individually set, . pre-set values vary depending on model.
Reduction of overall sensitivity changes alarm threshold but leaves coverage of
right/left channel unchanged.
Reduction of nominal range affects only coverage of long-range channel.
SW sensitivity [%]
Modifies the overall sensitivity within a bandwidth 50% - 150% for long range
(multichannel) detectors or 20%- 140% for mid-range (single channel) detectors.
Reduction of overall sensitivity changes alarm threshold but leaves coverage of
long-range channel unchanged.
22
26571_03
ADPRO PRO E by Xtralis
SW ATD
System Setup Manual
ON
Enables “Adaptive Threshold Determination”.
OFF
Disables “Adaptive Threshold Determination”.
Note:
SW Test (legacy
feature)
SW Vandalism
protection
OFF
Regular operation, Do NOT enable unless using legacy walk tester
CT-45 (default off).
ON
Enabled to perform walking test with legacy walk tester CT-45, do
NOT enable it for current walk tester CT PRO/ CT PRO 2.
ON/ OFF
Enables/ Disables “Anti-Tamper Protection”.
SW Mounting height HIGH
1)
Reset vandal
position
Mounting height above than 3 m (10 ft).
LOW
Mounting height less than 3 m (10 ft).
ON
Writes new alignment position into non-volatile RAM as baseline for
anti-tamper protection in case of misalignments.
OFF
Upload of settings to control device happens always automatically in
“OFF”.
-
Not selected.
Reset alarm counter ON
SW pulse count 3)
Disable ATD function prior to walking test to optimize
performance of detector.
When putting “SW Test” to “ON”, ATD function is disabled
automatically in Software mode.
Resets alarm counter to “zero” at next download of settings to
detector.
OFF
No resetting of alarm counter to “zero” at next download of settings to
detector.
-
Not selected.
0 - 10
Number of additional pulses (0 - 10) before an alarm is generated.
OFF
Triggers alarm on first pulse.
Notes:
1) Applies
only to long-range curtain detectors PRO-100/ PRO-100H and PRO-250H
2) Applies
only to directional detectors PRO-45 and PRO-45H
3) Applies
only to volumetric detectors
4) Applies
only to long range detectors PRO-100/ PRO-100H and PRO-250H
5) Applies
only to intrinsically safe detectors
26571_03
23
System Setup Manual
1.2.3
ADPRO PRO E by Xtralis
Output settings (PRO E-detectors only)
The detector allows to freely assign different output events to all available output relays.
Enter the output setting mode via top menu “Settings” → “Output Settings”.
Notes:
l
l
Accessing the Output Settings on a PRO detector will result in an empty window.
The output settings will be deactivated (grey) if connected to a PRO E-RF detector.
The “output setting window” allows to match 3 or 5 output relays (5 for H models) with any kind of event or
alarm the connected detector can create.
Example one, default settings, three outputs available, standard PRO E-detector, (screenshot below: PRO
E-45, single zone; thus out 4 and 5 greyed out, one zone, no pulse count event; default settings).
1. Alarm: 360PROtect™ (creep zone and behind detector) and main zone trigger output 1. Anti-masking
triggers output 1 as well, but together with output 3.
2. Tamper: tamper switch in main housing and in bracket and any misalignment trigger output 2.
3. Fault: Power supply or outside temperature outside of specified range (e.g. supply voltage too low,
outside temperature too high) failure or if the outside temperature is out of range of the specified
operational range. Anti-masking triggers output 3 as well, but together with output 1.
Example two, using all five relays available on a PRO E H-detector: (screenshot below: PRO E-100H, three
zones, no pulse count event; default settings).
24
26571_03
ADPRO PRO E by Xtralis
System Setup Manual
1. Alarm: Zones 1-3 (here: L, M, S) trigger output 1.
2. Tamper: tamper switch in main housing and in bracket and any misalignment trigger output 2.
3. Fault: Power supply or outside temperature outside of specified range (e.g. supply voltage too low,
outside temperature too high) failure or if the outside temperature is out of range of the specified
operational range.
4. Config1: Anti masking triggers output 4.
5. Config2: 360PROtect (creep zone) triggers output 5.
Example three, alarm localisation, each zone triggers its own alarm.
Example four, Legacy-mode, using only 2 Outputs: In case the PRO E-detector replaces an older PROdetector in an existing installation, you need to bundle the 5 Outputs into 2 Outputs to maintain all functions of
PRO E-detectors without changing the existing cabling.
26571_03
25
System Setup Manual
1.2.4
ADPRO PRO E by Xtralis
Oscilloscope View (Scope)
The Scope view is the most powerful feature of the software.
The software starts up in the scope view and will re-enter it at any time pressing the scope icon (
through the “tool” menu, clicking “scope view”.
) or
It shows in real-time the signal strength of each zone, if the monitored detector features multiple detection
zones. Simultaneously, it shows the actual alarm threshold, the general alarm status, and various parameters
such as total alarm count, strongest signal level received, and current settings of the DIP switches in the
detector, etc.
Through this menu you can manage the Scope view by stopping or running it, selecting the view mode,
increase or decrease signal speed, etc.
Scope menu appears as shown below:
26
26571_03
ADPRO PRO E by Xtralis
System Setup Manual
Scope view appears as follows (example PRO E-45):
The Scope view illustrates the cause/response relationship between inputs and output. The view shows all
signals and their levels on a time axis; it allows for a detailed analysis of the detector’s operation.
The Scope view appears automatically after a detector has been selected from the search list. The signals on
the screen represent the current readings of the detector and are helpful for resolving problems as well as
managing certain installation features.
The Scope window is divided into the following parts:
l
Scope view (black, left): Scope view is used to for signal monitoring; it shows IR amplitude, alarmthreshold and other vital parameters in real-time. In addition, it shows a varying amount of lines as
follows:
l
Green (Sensor Signal): shows the signal levels of the PIR sensor.
l
Red (IR Alarm): shows the IR event caused by the sensor signal.
l
Purple (output alarms): shows the actual output signal at relay, depending on model and setup up to 5
signals, General, Sabotage, Fault, Config1 and Config 2.
l
Blue (Alarm threshold).
l
Yellow (Vandalism Alarm). Shows the detector has been misaligned.
Note:
l
Alarms appear on Scope view only if the alarm generating detector is selected.
Table of Settings (top-right): This table shows the current settings of the selected detector; it consists
of the detector’s parameters such as sensitivity, desired detection range, their values and unit.
26571_03
27
System Setup Manual
ADPRO PRO E by Xtralis
To view the values of a certain parameter, click it, its values appear as shown below:
PRO E-100H
PRO-100H
The selected parameter’s values appear in view-mode only. Any changes made to the settings are directly
reflected on this table and the threshold. At the bottom is the firmware ID (FLD<>) and the used COM port
number with address of current detector.
Note:
Information displayed in table varies depending on detector model. PRO detector also show the real
time status of their DIP switches in the lower right corner.
You can control the Scope view through the following:
Action
Button
Shortcut
Run the Scope
Run
<F5>
Stop the Scope
Stop
<Ctrl> + <F5>
Select Scope view mode
Scroll Mode
<F6>
Grid
<F7>
Increase signal speed
Step up++
<F8>
Decrease signal speed
Step down- -
<Ctrl> + <F8>
Clear Scope view
Clear
<F9>
Delete all triggers
Trigger Delete ALL
<F10>
As shown in the table above, there are two scope modes:
l
l
28
Scroll Mode: If checked, the signal is continuous and its direction is from right to left. If unchecked, the
signal’s direction is from left to right and each time <F6> key is pressed the signal starts from the
beginning.
To switch between scroll modes press <F6>.
Grid: If selected, horizontal and vertical lines appear on the Scope in addition to the signals.
26571_03
ADPRO PRO E by Xtralis
1.2.5
Further features
1.2.5.1
Screen shot
System Setup Manual
This tool enables you to take pictures of the Scope view and save them in the “BMP” sub-folder accessed
through the ADPRO PRO E-Tool for Windows® folder. You can use them to compare readings, monitor
readings on certain times, etc.
To take a picture and save it, follow these steps:
1. Click “tool” menu” and “Picture take” or press the screen shot icon (
) and the following field appears:
2. Enter your comment,
3. Click “OK”.
The picture is saved as a BMP and as a PNG file and given a name according to the following naming
convention:
“Model-yymmdd_nnn.txt” where
yy
Year
mm
month
dd
Day
nnn
sequential number (1 - 999)
e.g. PRO_E-100H-140624_001.png
26571_03
29
System Setup Manual
ADPRO PRO E by Xtralis
To view a picture, open it from the computer, it appears as follows:
The image shows the scope, comment, and settings at the time that picture was saved.
The screenshots can also be viewed from the software itself as explained in the next section.
30
26571_03
ADPRO PRO E by Xtralis
1.2.5.2
System Setup Manual
Picture View
You can view the pictures directly from the Software for easier access by clicking “Picture view”. The
following window appears:
The window is divided into two parts: the left one lists all the pictures and the right a preview of the selected
picture.
To delete a picture, follow these steps:
1. Select the picture, its name is displayed in the field,
2. Click “Delete”. It is immediately deleted from this window and from the “BMP” folder as well.
To close the window, click (
).
Picture Auto
If this feature is checked, each time the detector reads a signal or detects a movement, a picture is
automatically taken and saved in the “BMP” folder.
Picture Memo
If this feature is checked, the “Picture take” tool is activated and you can take pictures of the Scope.
1.2.5.3
Statistics
Through this feature you can view data the detector transmits to the controller. The Statistics view logs the
actual alarm status of all detectors that have been discovered during the initial “Search for Detectors” process.
In addition to general alarm information, the view details the zone that issued the alarm. It also shows
warnings and detector‘s status under the system column. Every status change from every detector adds a
line in this log view.
This information is stored in text files on a daily basis, one file per detector. Files are saved in the “DAT” subfolder accessed through the ADPRO PRO E-Tool for Windows® folder.
Click “Statistics”, the following window appears:
26571_03
31
System Setup Manual
ADPRO PRO E by Xtralis
The window is divided into the following sections:
l
l
Connected Detectors (1): displays all connected detectors with information about identification number,
firmware version number and alarm counters.
Type (2): Each symbol indicates a status as follows:
l
(
): connected.
( ): not connected.
Log (3): displays the actual log.
l
l
To generate a statistics file and save it, follow these steps:
1. Enter file name,
2. Click (
Note:
32
) to start the viewing the transmitted data, it appears as in the example on the next page:
A line is created for each detected event, along with the date and event description.
26571_03
ADPRO PRO E by Xtralis
System Setup Manual
List of all connected detectors, their types, Firmware version and number of alarms since beginning of
recording. This example shows three Detectors connected, 4 and 5 have one Temper (T: 01) Alarm in the
counter (“T: 01”) The events are listed real time below (4 and 5 “System=-V” for Vandal).
Abbreviation
Event
GA
General Alarm
T
Temper
P
Power faults
CZ
Creep zone (PRO-E only)
Ax
Alarm in respective Zone S, M or L
Wx
Warning in respective Zone S, M or L
V
Vandal
Wx
Warning in respective Zone S, M or L
3. Click (
) to stop the process and save the file.
The file is saved in the “DAT” folder and named according to the following naming convention:
“STAz-yymmdd_nnn.xxx”
z
number of statistics file
yy
year
mm
month
dd
day
nnn
sequential number (1 - 999)
xxx
address number
1.2.5.4
Note:
Debugger
This feature of PRO E-Tool offers no benefits for commissioning, maintenance and fine tuning. The
debugger is specifically meant for software developers to debug their protocol implementation by
giving the opportunity to view, analyse and record the whole data stream of the RS 485 bus.
The debugger helps record all communication made between the detector and computer and save this
information in files stored in the computer. These files are saved in the “DAT” sub-folder accessed through the
ADPRO® PRO E-Tool for Windows® folder.
Click “Debugger” to open the Debugger window, it appears as follows:
26571_03
33
System Setup Manual
ADPRO PRO E by Xtralis
To start recording of data traffic and save this information in the computer, follow these steps:
1. Click the checkbox next to “Communication”, the window appears as follows:
2. Click “New File”.
Data is saved in the file; you can create another file by clicking “NewFile”.
To stop recording of data, click “Clear”.
Files are named according to the following naming convention:
“DBG-yymmdd_nnn.txt” where
yy
year
mm
month
dd
day
nnn
sequential number (1 - 999)
The following abbreviations are used in data recording:
Abbreviation
Error
ErrA
Error counter
ErrK
Error counter configuration
ErrW
Error counter working
ErrP
Error counter synchronisation
ChkSum
Error counter check sum
Tmo
Error counter timeout
Buf
Error counter buffer
34
26571_03
ADPRO PRO E by Xtralis
1.3
System Setup Manual
Uninstall Software
You might need to uninstall the ADPRO PRO E-Tool for Windows® for any reason; the Software enables you
to do so by providing you with a user-friendly wizard.
To uninstall the Software, follow these steps:
1. Open the folder in which you have installed the Software,
2. Double click on “unist000.exe”, the following message appears:
3. Click “Yes”, the following window appears:
4. Wait till the uninstallation process is complete, the following message appears:
5. Click “OK”.
26571_03
35
System Setup Manual
ADPRO PRO E by Xtralis
This page is intentionally left blank.
36
26571_03
ADPRO PRO E by Xtralis
2
System Setup Manual
iCommission
iCommission is a unique one-man-commissioning tool which helps to vertically align a PRO E detector from a
distance of up to 220 meters.
It consists of:
l
l
The iCommission unit, which hooks onto the vertical alignment screw on the detector.
The iCommission iOS app for compatible iOS devices (Apple iPhone, iPad, iPod touch).
Front view with user panel
2.1
26571_03
Rear view with WiFi antenna, 4mm Allen/Hex key driver and clamps
Front User Panel Overview
1
RP-SMA-connector
Use to install included WiFi antenna
2
Power LED
Lit when unit is switched on
3
Charge LED
Lit while unit is being charged
4
Motor LED
Lit while detector is moving up or down
37
System Setup Manual
2.2
38
ADPRO PRO E by Xtralis
5
Mini-USB port
Charge iCommission with USB charger
6
ON/OFF button
Press to switch iCommission on/off
7
DOWN button
Press to lower detector
8
UP button
Press to raise detector
iOS App Overview
1
WiFi indication
Shows connection status between iOS device and
iCommission unit
2
Speed selection
Roll to select speed of movement from slow (1) to fast (10)
3
Battery indicator
Shows charge level of iCommission battery
4
UP button
Tap for brief or hold for continuous raising of the detector
5
Down button
Tap for brief or hold for continuous lowering of the detector
26571_03
ADPRO PRO E by Xtralis
2.3
System Setup Manual
iCommission Installation and Alignment
To install the tool and align the detector, follow these steps:
1. Search for “Xtralis” in the App Store, scroll to the iCommission app and tap “GET” to install it.
2. Make sure that the iCommission unit is fully charged, using an USB charger and a mini USB cable, place
it on the vertical alignment screw of the PRO E detector as shown below:
3. Make sure that the 4mm hexagon driver connects inside the alignment screw and the outside clamps lock
properly on the bracket.
4. Switch on the unit by pressing the left button until the LED switches on. After a few seconds, the
iCommission creates its own WiFi hotspot with the following details:
SSID:
iCommission-by XTRALIS
Password:
12345678
26571_03
39
System Setup Manual
ADPRO PRO E by Xtralis
5. Use the up/down buttons on the front panel to rough-align the detector (see the ADPRO PRO E PIR
Installation Manual, document no. (27386), section "Alignment with the help of the telescope").
6. Perform walk test at ¼, ½ and full nominal range.
7. Use CT PRO 2 (see the ADPRO PRO E PIR Installation Manual, document no. (27386), section "CT
PRO – wireless walk tester"), iPIR app with FastTrace 2 or remote controlled PC running PRO SW to
determine performance and fine tune sensitivity.
If performance is still unsatisfactory, start the iCommission app and remotely change the vertical
alignment up or down until the required performance is reached.
40
26571_03
ADPRO PRO E by Xtralis
System Setup Manual
When the detector has full performance across the desired range, the vertical alignment is done and the
iCommission unit can be removed. Continue with the commissioning process.
26571_03
41
System Setup Manual
ADPRO PRO E by Xtralis
This page is intentionally left blank.
42
26571_03
ADPRO PRO E by Xtralis
3
System Setup Manual
PRO E-IPM (IP Module)
ADPRO PRO E detectors have RS-485 interfaces which allow for remote maintenance and full alarm
management via up to 1000 m long field bus connection. (see the ADPRO PRO E PIR Installation Manual,
document no. (27386), section "Multiple detectors at interface module IFM-485-ST").
Using the IP Module (IPM) converts this RS-485 bus to Ethernet and makes it available remotely through the
IP address of the module.
The following instructions show how to set up and prepare the IP Module and how to create a Virtual COM
Port (VCP) on a PC in order to access the detector connected to the IPM.
3.1
System Overview
This overview shows all three parts of the system: the workstation, the PRO E detector and the data
infrastructure in-between.
Workstation:
The ADPRO software (see "PRO E-Tool Software" on page 3) needs to connect to a serial COM port to
access the detectors. Normally this is a regular RS-232 COM port, which then gets converted to RS-485 and
can directly communicate to detectors on the bus. If there is a USB connected RS-485 converter, the COM
port used is a Virtual COM Port (VCP) which is created by a driver (VCP driver from FTDIchip.com) to direct
the data stream from the USB port to the PRO Software.
When using the IP Module, you need a driver (com2tcp) to create a VCP from the IP address. This VCP
cannot be same as the one the PRO software connects to, so another VCP should be created and then
connected to the other VCP through a Virtual Null Modem Cable (com0com driver).
26571_03
43
System Setup Manual
ADPRO PRO E by Xtralis
Detector:
The IP Module should be configured to have a known IP address (using the Lantronix DeviceInstaller) and
then connected to a Power over Ethernet (PoE) enabled switch.
3.2
xPico Module Setup (PRO (E) Series Detector)
The main component of the IPM is an xPico module which should be configured, to do so follow these steps:
1. Install the "Lantronix DeviceInstaller" software (follow the steps available on:
http://ltxfaq.custhelp.com/app/answers/detail/a_id/644 or via the Lantronix website:
http://www.lantronix.com)
2. Switch the network card over to the network where the xPico module is located.
Note:
To locate the network, start the DeviceInstaller and press <F5> to refresh the environment.
When xPico module and PC are on the same network, the device appears in black letters in the
configuration screen, while if the module is on another network (e.g. if the subnet is different), it appears in
red letters.
If the network on which the xPico is located cannot be accessed, you can use the Assign IP button to
switch the xPico module to another network. In case this fails, try connecting the PC and xPico module
via a standalone network switch without connection to other networks and set the PCs network settings
according to the existing network configured in the xPico module.
44
26571_03
ADPRO PRO E by Xtralis
System Setup Manual
3. Double-click the xPico module, the configuration screen appears as shown below:
If you receive a new xPico module, the connection mode may not be configured correctly. To fix this,
connect via the telnet interface as shown next:
26571_03
45
System Setup Manual
ADPRO PRO E by Xtralis
4. Press Enter within the first 5 seconds after connecting to enter the device setup mode as shown below,
otherwise the telnet server on the xPico module will disconnect and should be connected again:
Upon successful connection to setup mode on the xPico module, an option menu appears.
5. Choose "1" to change channel 1 settings as shown next:
46
26571_03
ADPRO PRO E by Xtralis
System Setup Manual
6. Press Enter to select the default settings and enter "C0" in "ConnectMode" option as shown below:
Note that most settings can be left according to default values.
7. Proceed with the settings. When done, the main menu appears,
8. Select "9" to Save and exit the new settings then press Enter.
The Telnet configuration is now done. You can configure the other settings using the Web Configuration
Tools.
26571_03
47
System Setup Manual
ADPRO PRO E by Xtralis
To configure the settings, follow these steps:
1. Enter the username and password which are left blank then click OK, as shown below:
2. Press Enter.
The Device Server Configuration Manager can also be accessed via regular web browser as shown next:
48
26571_03
ADPRO PRO E by Xtralis
System Setup Manual
3. Configure the xPico Serial Settings using the values mentioned in the below image:
4. Click OK to save the configurations locally. This does not transmit the settings to the xPico, this process
is explained in the next step.
26571_03
49
System Setup Manual
ADPRO PRO E by Xtralis
5. Configure network settings of the xPico module. If the Detector is on the same network as the attached
control system (e.g. computer running ADPRO software), enter a Gateway IP of all "0"s to disable routing
as shown below:
6. Click OK at the bottom of the page to save the configuration parameters locally.
7. Click "Apply Settings" from the left menu to transmit the saved settings to the xPico.
50
26571_03
ADPRO PRO E by Xtralis
System Setup Manual
When the transmission is complete, the detector connected with the xPico module can be accessed via
Serial-over-Ethernet connection as explained in the next section.
3.3
PC Setup (com0com with com2tcp)
After installing the com0com software, configure the virtual COM ports, this step and changing the com0com
settings are done through the com0com Setup screen as shown below:
Notes:
l
l
The "emulate baud rate" checkbox is optional, as the baud rate will be controlled by com2tcp.
The only required connections are "RX" and "TX", each of them is crossed to the other on the second port.
Other connections can be left as they are or configured according to the above image (should a different
setting exist).
After configuration is done and the system is set up, start the batch file "PoE_SoE_startcom2tcp.bat".
Note:
26571_03
If different parameters are used in the xPico Module setup (e.g. IP address or port number), make
sure to change those parameters in the batch file too.
51
System Setup Manual
ADPRO PRO E by Xtralis
This connects the workstation virtual COM1 port to the xPico module, so that the ADPRO software (or any
other control software) can access the detector via COM2.
Alternatively, you can use any other TCP serial tunnel software in raw data mode (not telnet mode). If telnet
connection mode is desired, change the xPico settings accordingly.
When the setup is finished successfully, you can access the detector for example via the ADPRO software:
52
26571_03
ADPRO PRO E by Xtralis
3.3.1
System Setup Manual
Connecting Multiple Detectors
When connecting more than one detector, the number of virtual serial ports in the workstation should be
adjusted since every detector needs two virtual serial ports, one network-sided and another one linked to the
application. For example, if you have 3 detectors connected via Ethernet, you will need 3 pairs of linked virtual
ports in com0com as shown below:
To configure com2tcp (network-) connection details, modify the corresponding parameters in the "PoE_SoE_
start_com2tcp.vbs" file:
Once the configuration is done, start the "PoE_SoE_start_com2tcp.vbs" file. When the connections are
successfully established, start the ADPRO Software and select the corresponding COMx port for the detector
you want to access.
26571_03
53
System Setup Manual
ADPRO PRO E by Xtralis
Notes
54
26571_03
www.xtralis.com
UK and Europe +44 1442 242 330
D-A-CH +49 431 23284 1
The Americas +1 781 740 2223
Middle East +962 6 588 5622
Asia +86 21 5240 0077
Australia and New Zealand +61 3 9936 7000
A Disclaimer about this document, statements about Intellectual Property, Copyrights, and Liability, as well as a General Warning are
available in an earlier section of this document.
Document No: 26571_03