Download SLICE User`s Manual, version 1.0 - final
Transcript
Cable Installation Recommendations • Flat braided ground cable has lower impedance than typical round wires and hence makes a better ground connection. • Never assume that connections are good until you check them with an ohmmeter. Should be <1Ω for short runs or <5Ω for long runs. • Ground cables inside test dummies should be braided type with a 12gage equivalent size. • Ground cables from a test article or vehicle to the SLICE Stack should be braided strap type with a 15-gage equivalent size. • The cable from a test article or vehicle to the Earth connection should be large enough to create an a low impedance connection given the distance between Earth connection and test vehicle. 8 to 12 g gage g equivalent q is common. • If braided cable is not available, any ground wire is better than none! © 2009-2010 DTS Principles of Dynamic Data Acquisition