Download Chapter 6 Action Plan
Transcript
APPENDIX 2- b) b) Battery Iu × Autonomy (days) Depth of discharge×Inverter efficiency Battery capacity (Ah) = = 11.58 (Ah)×3(days) 0.7×1.0 = 49.63 (Ah) You must choose Deep cycle battery that capacity is more than 49.63 Ah. c) Charge controller Capacity of a charge controller must be more than Isc. And in the case of a DC system, Capacity of a charge controller must be more than load current. Maximum (starting) current varies on a kind of appliance, and there are generally as follows. Lights : rated current × 1 ~ 2 TV : rated current × 2.5 ~ 5 Motor : rated current × 5 ~ 10 In this case, load current are follows. appliance Light Rated current (A) 0.67 Maximum current (A) 0.67×2= 1.34 W&B TV 2.5 2.5 ×5=12.5 Radio 1.25 1.25×2= 2.5 Maximum load current (A) = Lights rated current + TV maximum current + Radio rated current = ( 0.67×2Qty ) + 12.5 + 1.25 = 15.09 (A) > 3.38 (A):Isc You must choose Charge controller that capacity is more than 15.09A. If possible, capacity had better increase 20% for safety factor, In this case, Charge controller capacity is more than 18.11A is better. Code of Practice for Off-grid Photovoltaic Systems 9