Bit #
Assignment
bit 2 ESCAPE
0 - C-Frame active
1 - C-Frame ignored
bit 3 2Mb loops
0 - Subscriber
1 - Network
bit 4 Loop 2 or Loop 3
0 - Subscriber
1 - Network
bit 5 Loop 2 instruction
0 - Active
1 - Non-active
bit 6 Loop 3 instruction
0 - Active
1 - Non-active
bit 7 HDB3 command
0 - Active
1 - Non-active
bit 8 Loop acknowledge
0 - Acknowledge
1 - No acknowledgment
bit 9
Not defined...
bit 10 Local Fault
0 - Active
1 - Non-active
bit 11 Remote/ Line fault
0 - Active
1 - Non-active
bit 12 C Frame loss
0 - Active
1 - Non-active
bits 13-15 Spare
3) L1-Rx
Options: 1-15, 17-31
Select the desired Line receive timeslot on which to receive Cbits.
•Press NEXT (F1), or PREVIUS (F2) as needed.
Because PCM-30, MFAS, framing is required, you may not select
Ch.3 Menu Descriptions
3-59