Download Technical Description - SMA Solar Technology AG
Transcript
Sunny Boy 2000 Technical Description Preparing the connection The front panel of the inverter must be removed in order to attach the output wiring this is done by removing the four screws (M5) accessible from the front. The front panel is grounded with a tab and receptacle connector - carefully remove the green-yellow cable in order to remove the front panel. You can now see the position of relevant modules and clamps in the open case in front of you. You will find: • The plug connectors for PV-panel connection • The mains terminals (in the lower middle to right section) • The mains fuse (in the lower middle to right section) + thermally monitored varistors + PV-panel connectors mains fuse (12.5 A, slow blow) mains connectors Fig. 3.4: Connectors in the Sunny Boy 2000 SB2000-11:EE - 23 - SMA Regelsysteme GmbH