Hint! You can open sdp file with the VLC player to view the stream, but notice the following requirements: Stream port number should be even number. If you are using multicast stream, ensure that you have set valid multicast IP address. Make sure that windows firewall is turned off. MAIN PAGE The MAIN PAGE is opened after the WebUI session has been established to the MPH100/400 series video encoder. MPH100/400 encoder contains maximum six (6) encoding profiles, which can be individually configured. On this page you can see each profile’s current status and start/stop their video streaming. Type: Serial Number: HW Version: SW Version: Uptime: Current time: Self Test Result: Current Temperature: PROPERTIES Device type (configuration map code) Device serial number Device hardware version Device firmware version Device uptime Device current time Device test result Current ambient temperature STATUS Type: Encoder: Multicast /Unicast: Target Address: Target Port: Camera Status: Stream Status: SDP: Here you can see each profile’s current status. Stream type (Video) Encoding format (H.264/MJPEG/MPEG-4,MPEG-2) Video transmission mode (multicast/unicast) Multicast: Multicast IP address / multicast group Unicast: IP address of receiving decoder UDP port number Camera status (Ok/No signal) Video stream status (On/Off) Link to SDP file (Session Description Protocol). The SDP file contains stream parameters that are meant for 3rd party applications (e.g. SW decoders) to open/view the stream. Download short term logs: Debug log file Download long term logs: Debug log file 11 MPH100/400 series video encoders WebUI user manual