Download AQUASIM 2.0 Tutorial
Transcript
5.2. ADVECTIVE-DIFFUSIVE REACTOR COMPARTMENT 123 5.2 Advective-Diusive Reactor Compartment The example of this section demonstrates how to calculate the transport of a substance through an advective-diusive reactor. The main AQUASIM feature introduced in this section is the advective-diusive reactor compartment. Problem Part A: Calculate the break-through curve of a rectangular tracer pulse of the form (arbitrary units) time t inow concentration C 0.00 0 0.01 1 1.00 1 1.01 0 through a column with a cross-sectional area of 1 unit, a length of 1 unit, a discharge of 1 unit, and a dispersion coecient of 0.1 units (arbitrary units). Compare the inow concentration given above with the concentration time series at the end of the column. Part B: Dene a samling device with a volume of 0.01 units and link it advectively to the outlet of the column. In addition to the concentration time series dened above, plot the concentration time series at the start position of the column and within the sampling device. Discuss the dierences in the plotted curves.