Note
36 • FXO interface configuration
Use the battery-reversal disconnect signal with caution, and use only if the
battery-reversal connect signal is also enabled.
Configuring how to detect an outgoing call is connected (optional)
An FXO interface has the following methods for verifying the connection of an outgoing call after the dialing
has been completed:
• Detect battery reversal (if provided by the FXS switch)
• Detect the first tax pulse (if provided by the FXS switch)
Note
Tax Impulse Signals: European telephone companies in Austria, Belgium,
Czechoslovakia, Germany, Spain and Switzerland place a pulse signal on the
phone line to meter the length of the telephone call for billing purposes.
The command to enable or disable these methods is connect-signal. If both are enabled, only one needs to
occur for the FXO interface to verify a properly connected call with the remote party. Should both be disabled,
the SmartNode waits for the call-connect signal from the FXS switch.
Mode: Interface FXO
Step
Prompt, command & response
1
2
node>
node>enable
node#
3
node#configure
node(cfg)#
4
node(cfg)#context cs
node(ctx-cs)[switch]#
5
node(ctx-cs)[switch]#interface fxo if-name
node(if-fxo)[if-name]#
6
node(if-fxo)[if-name]#[no] connect-signal
{battery-reversal | tax-pulse}
Purpose
Basic prompt in Operator Exec mode
Enters Administration execution mode
Response: The prompt in administration
execution mode is the #
Enters the Configure configuration mode
Response: The prompt in the Configure
configuration mode is (cfg)#
Enters the Context CS configure mode
Response: The prompt in the Context CS
configuration mode is (ctx-cs)[switch]#
Enter the Interface FXO configuration
mode
Response: The prompt in the Interface FXO
configuration mode is (if-fxo)[if-name]#
Selects battery-reversal, tax-pulse or neither to determine when outgoing calls are
connected.
Default: both methods are disabled.
Note
Only disable connect-signal if you are sure that the FXS switch provides a
call connect signal.
FXO interface configuration task list
412
Related documents
BMW 318I Automobile User Manual
AV5462
Patton electronic ONSITE 2800 User's Manual
X-PRO User's Guide
DataHopper 900STN User Manual
EasyLynq - Manual de instalação
Rapport 2006-2007 - Province de Hainaut
picoTCP User Documentation
A Transit Telephony Exchange Simulator Implemented in Erlang
Data Interface Control Document v.5 - ESO
Programming Manual, PowerFlex 700S AC Drive
o expliquer