Download SmartNode Series SmartWare Release 3.20 Software Configuration
Transcript
SmartWare Software Configuration Guide
36 • FXO interface configuration
Mode: Interface FXO
Step
1
2
3
4
5
6
Prompt, command & response
Purpose
Basic prompt in Operator
Exec mode
node>enable
Enters Administration execution mode
node#
Response: The prompt in
administration execution
mode is the #
node#configure
Enters the Configure configuration mode
node(cfg)#
Response: The prompt in the
Configure configuration
mode is (cfg)#
node(cfg)#context cs
Enters the Context CS configure mode
node(ctx-cs)[switch]#
Response: The prompt in the
Context CS configuration
mode is (ctx-cs)[switch]#
node(ctx-cs)[switch]#interface fxo if-name
Enter the Interface FXO configuration mode
node(if-fxo)[if-name]#
Response: The prompt in the
Interface FXO configuration
mode is (if-fxo)[if-name]#
node(if-fxo)[if-name]#dial-after {dial-tone | timeout seconds} Specifies whether to dial
after detection of dial-tone
(default) or to wait for a
specified timeout (in seconds). Zero (0) seconds will
initiate dialing immediately
after going off-hook.
node>
Example: Setting the timeout to be 4 seconds after going off-hook when initiating a call. The timeout is set for
the FXO interface named Line0.
node>enable
node#configure
node(cfg)#context cs
node(ctx-cs)[switch]#interface fxo Line0
node(if-fxo)[Line0]#dial-after timeout 4
You can verify the change in configuration by using the show running-config command.
This is one of the few commands that does not have a no inverse operation of the command. If you want to
change the timeout period, re-enter the command with the new timeout period. The other option is to wait
for dial-tone. To return to the default (waiting for dial-tone before dialing), enter the command again
using dial-tone.
FXO interface configuration task list
409
Related documents
BMW 318I Automobile User Manual
AV5462
Patton electronic ONSITE 2800 User's Manual
X-PRO User's Guide
DataHopper 900STN User Manual
EasyLynq - Manual de instalação
Rapport 2006-2007 - Province de Hainaut
picoTCP User Documentation
A Transit Telephony Exchange Simulator Implemented in Erlang
Data Interface Control Document v.5 - ESO
Programming Manual, PowerFlex 700S AC Drive
o expliquer