Download SmartNode Series SmartWare Release 3.20 Software Configuration
Transcript
SmartWare Software Configuration Guide
43 • FXO port configuration
Mode: Configure
Step
Command
1
node(config)#port fxo slot port
2
node(prt-fxo)[slot/port]#caller-id foroptional mat { bell | etsi }
3
node(prt-fxo) [slot/port]#flash-hook
optional duration duration
Other FXO port parameters
Purpose
Enter FXO port configuration mode
Specifies which line protocol is used for caller-id
transmission. Use bell for US / Canada, etsi for
Europe.
If caller-id is not enabled or wrong configured,
detection of caller-id is not possible. Default: etsi
Specifies for what time the SmartNode should go
on-hook to signal flash-hook to the CO. Default of
duration is 200ms, for US and Canada try 350ms
or higher.
528