Download gcs-2 gcs-6 clock synchronizers - MICRO-AIDE
Transcript
GCS U ser M anual Duration – The GCS always attempts to set the time and date for each assigned Target Device. Typically, 15 to 20 seconds are required to set the time and date for each Target Device. Latency Compensation – The Terminal Ports implemented on all MICRO‑AIDE CWR, VDL and PSM products are designed to support high speed, machine-driven interfaces (e.g., a PC running GEA software). Each is prepared to accept and execute time and date commands immediately. Furthermore, as each character that comprises the command string is received, it is acted upon by the device. No echo character check is required by the GCS. Consequently, no delays are introduced between characters and the entire command can be sent in 9 msec (35 characters, 10 bps at 38,400 Baud). This is not the case with the HCA, EC‑4 (216DL module) and HXP‑3. The HCA and EC‑4 serial interfaces require that each character sent be checked against an echoed char‑ acter. This introduces delays as the GCS must wait to receive the echoed character. The HXP‑3 does not echo characters. To assure good performance with the HXP‑3, the GCS imposes a .5 second delay between each character that it sends. From start to finish, the time set command for these three products will take several seconds to send. The GCS is designed to compensate for this characteristic, which would otherwise result in an unac‑ ceptable time discrepancy. The time set command is always preformulated with a clock setting that is several sec‑ onds ahead of the current GCS time. By way of example, suppose the worst-case delays in total will take the time set command 8 seconds to be sent. The command will include a clock setting that is advanced by 10 seconds. After the command is entirely sent, the GCS will wait until 10 seconds have precisely expired. The carriage return character is then sent and the Target Device clock is updated. The GCS and Target Device clocks will differ by a very small amount related to the execution time of the Target Device. C GPS Signal Loss – The sequence will be initiated and completed irrespective of the GPS signal status. This applies even if the Alarm Output is active indicating a loss of GPS signal for seven or more days. The internal real-time clock used by the GCS has an accuracy specification of ±.26 seconds per day. Even without GPS-based synchronization, the GCS clock will be significantly more accurate than the real-time clock used by any Target Device other than a MICRO‑AIDE CWR‑24E, CWR‑72E, CWR‑264XL or VDL. The latter use the same real-time clock chip with an accuracy rating of ±3 ppm. Log Entries – The success or failure of each clock set attempt (automatic or manual) is noted by an entry in the Log. Alarm Activation – Three consecutive failures to set the clock at any given Target Device will activate the Alarm Output. Failures can be the result of either an automatically or manually initiated sequence. 82 M icro ‑A ide