Download SWING GATE OPENER SW43O SERIES
Transcript
USER'SMANUAL SWING GATE OPENER SW43OSERIES + 3.00mmax 200k9max 3.00mmax 200k9max lmportantSafetyAdvice: regulations is required. 1. Knowledge of therelevant electro{echnical is necessary. 2. Training in useandmaintenance of safetyequipments whensomemechanism assistance is required adjustment is needed. 3. Professional 4. Alwayslaymainsandcontrolcablesseparately. beforeinitialoperation. 5.Testeveryequipmenl 6. Makefamiliar withtheuseof thesvstembeforeinitialooeration. Gontentof the Kih x2 Actualor x2 Remot€ Control W". K,, War.ing Light lnlock/ @* x4 Fixing brack€l for pill6r Key to harlally Fixing bracket for gate Wiring Diagram! ControBox M i n .1 s c m <1 \ Fixingpartfor pillar lmportantSafetyAdvice: '1. Knowledge electrotechnical regulations is required. of therelevant of safetyequipments is necessary. 2. Training in useandmaintenance is required whensomemechanism assistance adjustment is n e e d e d . 3. Professional 4. Alwayslaymajnsandcontrolcablesseparately. beforeinitialoperation. 5.Testeveryequipment withtheuseof thesvstembeforeinitialoperation. 6. Makefamiliar Contentof the Kit: x2 Actuatol 8'" @",K*, Key to manurlly rrlock @_ ,<4 Fixing bracketfor pillar Fixing bracket for gate Wiring Diagramr ConvoBox Min.'1scm .1 \ Fixing part for pillar lnstruction of Installation: 1. Assemblethe metalfixingbrackersfor the gatepollars. Andthenfixthebracket to thepillar IMPORTANT lf the hingeof yourgateis morethan21ommfromthe edgeof the pillat il is necessary to adaptthe pillarto ensuresthe hinge is lessthan210mmfrom theedgeof the pillar. tiNcoRREcA 2. Fixthe actuatorto lhe fixingbracket. 0 ' r ! f| E 3. Unlockthe actuatorandadjustthe stemof the actuator. Normally, thefactorypresetis already1ommfromtheendof the stroke. if it is difficultto movethe stemby hand,drivejt electrically to avoiddamageto thegateor kit. OPEN SW 43O Version 1.0 Page "t " 4. Fjx the metal bracketon the gate and checkthat the actuatordoes not touch the pillar. lf this is the case, it will be necessaryto make a notch in the cornerof ihe pillar. I of thegatemanually. lt mustmovefreelyby itself. 5. Testtheopening in another lf not,youmustinserithestemof theactuator of thefixingbracket.. problem. lf no lockthe actuator. CLOSE 6. The positionof the stopendsdependson the distance(E)of the gatehingefrom the edgeof the pillar.The tablebelowgivesthe positionof the stopend according to (E). angle E<12mm 12mm<E<67mm 67mrn<E<123mm 12A' ta' 1oo" 123mm<E<210mm 90' Thesystem is readyto program andoperate. sw 430 Version 1.O Page -2 - GonnectionDiagram ThermalFuse F230 Backupbattery V Ac in 230VAC out for GardenLamp 12VDCinoutfrommainPCB To Backu Totransformer 12VAC ( 1 2 vD C ) Dio Switches - | ? Colorindicationfor motorw:re: Elack wire for . Red wire for + i.. ':- t2v Dc Antenna Actuato12Warnino Lioht PHOTOCE!L PHOTOCELL SENDER RECEiVER @ Ground To externalopen/closeswitch To externalGardenLamoswitch Forexternal LEDdispla GardenLamol\y'anual Button l\,4anual Button Open/close 12VDC outoutto smallPCB N o z sw 430 Version t.O Page -3- Transformer AG Wiring ! <-\ I Insideof the controlbox,thewiring should be likethe photoon the left. Opening/ ClosingLearning: Pleaseproceedthis functionbeforeusinglhis product,otherwisethe systemwill drive the gatesimproperly,E.g.iThegatecan'tclosecompletelyor can'topento lhe inlended degreewith somestrokelengthleft unused. press" Auto"butiononthePCBfor3 seconds Toactivate thisfunction, whilethePCBis on. "Auto" the button,it willentertheopening/closing learning modeas below: Afterrelease \{illclosethegatesfirst. 1.Thesystem Auto Pleaseremove anyobstacle couldpossibly blocktl-'egate. Beforeihe aciuators sta|i,thewarninglightwillblinkfor3 seconds. 2 willclosefirst.andthenActuator close1 secondlaier. ThenActuator Actuator 1 willopenthegate1 fully, 2.After3 seconds, Actuator 2 willopentheothergate2 fully. waitingfor3 seconds, Actuator 2 willclosefulyflrst,waitingfor3 3.Aftef3 seconds Actuator 1 willclosefullv. seconds, 4. Systemrepeats theac*onsof point2 and3 onemoreiime. checksoperation ofActuator 1 andActuator 2 together. 5.After3 seconds, systern process 6.Afterlearning succeeded, thesystemis readyforuse. whichmeans lf thesystem blinks afterthislearning mode, learning invain, pleasemakesurethatthere'sno obstacle on theway, thelearning modei thentryagaintotrigger NOTE: TheOpening/Closing Learningcouldn'tbe donesuccessfully dueto the over-weight of the gates.Therl,the CurrentLimit needsto be adjusted.Pleasereferlo P7 of this manual. lf any assistanceis needed,pleasecontactthe techniciansof our agenl. sw 430 Version {.O Page -4 - RemoteLearning(activationof remotecontrolfor gateand lampoperation): To activatethe .emotecontrolservice,pleaseproceedthe followingstepsl the Gates) A. RF gatelearninq:{for Open/Close "RF" keyon the PCBfor over2 seconds 1. Press whilethe PCBis on. 2. You'llseethe LEDlighton (learnilgmodeentered). pleasepressany key on the remotecontfol, succeeded) LEDwillnowb nk for 3 times(learring wlthout blinking light off after 10 seconds or (learning failed,pleasetry againthewhoieprocess). 3. Pleasereoeatthe sieD1 and 2 to activateanother femotecontrol,othefwisethe unlearntremotecontrolwon't bythe system. be recognized TurningOn/Offthe Ga.denLamp) B. RF lamplearning:(for "RF key with lamp" on the PCBandanotherkeyon the femolecontfolas step1-3 above. Pfoceed Note:Upto 8 differentRFremotecontrolkeyscanbe learntfor eachfunction by this system(gates& GardenLamp). RemoteControl: Choosetwo of the four keysto proceedRF learning, The rest of the keysare availablefor otherpurposessuch as GarageDoorOpener. The remotecontrolhas4 keyson it, andchoosetwo of themto proceedRF learningfor one-keygatecontroland lampcontrolseparaiely. (open,closeandstop)by remotecontrol: Operation openthegate,nextpressto slop,nextto operation is verysimple: onekeypressVr'ill Theremote soon closeihegate,nextto stop...and Whenopeningthegates: 2 opens. thenActuator 1 opens, 4 seconds latertheActuator lightwillblinkfor3 seconds, 1. Warning warning lightblinksuntiinextcommand Actuatofs revefse for3 seconds 2. lf thegatehitssomething, recetved. Whenclosingthegates: thenActuator 2 closes, 4 seconds latertheActuator 1 closes. lightwillblinkfor3 seconds, 1. Warning reverse for3 seconds warning lightblinksuntilnexlcommand Actuatorc 2. lf thegatehitssomething, recetved. Lampcontrol(onandoff)by remotecontrol: the "RFlamp"learning. Simplyswitchon andoffihe lampby the keywhichhadproceeded gateoperationworks properlyonly aftersucessfulOpening/Closing Learning. Remark:The sw 430 Version l.O Fag6 -5 - Photocell(Optional): 1. DuringOpening: hasbeenintercepted, systemwilli Whenihe loopof photocells 2 hasbeenactivated.OR A. ignofe,if theActuator 2 hasn't beenactivatedyet. halt, if the Actuator B. 2. DuringClosing; hasbeenintercepted, systemwillstopclosingthe gatesandthen Whenthe loopof photocells untilthesetposition. openbothgaiessimultaneously Autoclose: dependson yoursettingof 30 secondsor 60 secondslater(onlywhenthisfunclionis enabled, thenActuator 2 closes,4 secondslater key1 of dipswitch), warninglightwillblinkfor 3 seconds Actuator1 closes.Whenthe processfinished,waminglightwill be switchedoff. Manualgatescontrolon the PCB: 1.Theoperationis the sameas remote:one key p.esswill openthe gate,next pressto stop,nextto so on. closethe gate,nextto stop...and wallbuttonis avaliable.(Connected to O/C& GNDterminals) handsetor external 2.Optional M a n u alla m po n : lampon" key. switch onandoffthelampbythe"Manual Simply GlearRF memory: "Clear" while lhePCBison. keyonthePCBforover2 seconds Press for 2.5secondsthenthe RF memoryhasbeencleared. You'llseethe LEDblinking Reset: "Clear"keyfor over2 seconds. Press"Clear"keyon the PC3 andinputACpowerikeeppfessing You'llseethe LEDblinkfor 2 secondsandlighton for 3 secondsthenlightofl. actionshavebeencarriedout,all RFdatawillbe cleared. Oncethe mentioned Quickrelease: Usethe Keyto unlockthe actuatorto movethe gatesmanually. GIulchadiustment: protection. insidetheactuator as an additional TheSW430seriesfeatufea cluichmechanism p'o'essional for lheclutchrequires assislance. AnyadjLStrnent copyright@ SW 430 Version l.O Page -6 - Settings of Dip Switches: I X nF IX Xl I l nI I ON € = Thedefaultsettingof dipswitches. * = 5l tl 1 Kev No. I 2 3 4-8 Function Auto-Close Auto-CloseTimer GateType CurrentLimit ON Yes 60 Sec Hea\y Gate selected OFF No 30 Sec Light Gate unselected NOTE: The current limit settingcould be neededto adjustmentaccordingthe weight of the gates during Opening/ClosingLearning, Approx.currentlimitvaluesfor differentdip switchsetting: switch4 s w i t c l5r sr,vitch6 switch7 switch8 ,1.5A 2.0A 3.0A 1.0A ON [XX:€€€*€r *n[lEEnfln 1 2 1 4 : 6 7 Altoff 5.2A Limit(meansalsotheworst Maximum Current sensibility, couldshorten thelifeof motor,please try lowercurrentlimitfirst) S o\ lF=*,ffitr1ltll =nEEn[tIEj 1 2 i 4 5 6 7 CurrentLimit SecondHighest 6 ON [€*r[Elllr xn[i=EInn] ''r'-!"'i--'i-'i-r r r oN l\y'inimum CurrentLimit Whenuserswitchesseveralswitcheson, for safetyreason,sysiemwill choosethe lowest (switch4insteadof switch6 or 8) currentlimitsetting automatically. n€€in*xflxxni x[ni=tr&n&] 1 2 . i 4 5 6 ? S copynght@ SW 43O Version 'l.O Page -7 - 8 Optional Accessories: E o o o o s> c I Set of Photocell Operationof Photocell: site,whefethesenderandreceivef canbe alongthesameline Selecta properinstallalion to theopener'sPCBas wiringdiagramabove. andat thesameheight. Connect Poweron the syslem,try and see if it worksproperlyby interruptting the lR between fof times.Therelayin the receiver thesenderandreceiver shouldrespondaccordingiy wl-ileI FD swir.lesON ard OFF. wellinstalled, whileit'siriggered duringopening Withphotocell the gates,thegateswillignore theinteffuption andopen.Whileit'striggered duringclosingiiregaies,thegateswillreverse for untillnextcommand sent. 3 secondsandstopandwarminglightwillkeepblinking Specificationsr lvlodel PowerSupplv l Power forlvotor : I\,4aximLrm GateWeiqht l\,4axlmurn GateWidth StrokeLenqth Ddve 90"Operaiing Time DulyCycle Ternperature Operation OvefloadProtection girgBattery Backuo Rechar FoLrdator AutoGateClose . : SW43O 230VACt10% 50Hzi110VAC60Hzavailable 1 2V D C (440lbs)x 2lVax. 200KGS + 3.0[,4 (2( 3.01V (1sin) 350mm Acl\.4E :l, around'15Sec 120"[,4a x. 20r/o :, Yes Yes( Not/ncluding Battery 12V,7A/,) Adjustable timer(off/30/60sec) Terminal Extension RFCarriage ControlRange Sw 43O Version 1.O .:,, ' 3'15lilH/433.92[/Hz )rox.30-50Meters Page -8-