Download MV1000/MV2000 Communication Interface User`s Manual
Transcript
Chapter 7 7.1 Specifications 1 Ethernet Interface Specifications Basic Specifications Electrical and mechanical specifications:Conforms to IEEE 802.3 (Ethernet frames conform to the DIX specification) Transmission medium type: 10BASE-T Protocol:TCP, IP, UDP, ICMP, ARP, FTP, HTTP, SNTP, SMTP Maximum Number of Connections and Number of Simultaneous Uses The following table indicates the maximum number of connections, the number of simultaneous uses (number of users that can use a function simultaneously), and the MV port number for each function. Function Maximum Number of Connections Setting/measurement server Maintenance/test server FTP server Web server (HTTP) SNTP server Modbus server Instrument information server 3 1 2 1 – 2 – Number of Simultaneous Uses Administrator User 1 21 1 11 2 21 – – – – – – – – Port number4 2 3 4 5 34260/tcp2 34261/tcp2 21/tcp3 80/tcp3 123/udp3 502/tcp3 34264/udp2 6 7 Specifications 1 Users have limitations. See section 1.1 for details. 2 The port number is fixed. 3The default port number. You can set a value in the range of 1 to 65535. Use the default port number unless there is a specific reason not to do so. 4 Make sure that each port number is unique. App Index M-4662 7-1