Fig7: The complementary sub-models of the GNSS model made of several sub-models
Then, for testing purpose, one can define a stub to integrate the models with the required system
interfaces. This is what is achieved in the next diagram where we see on the right part the various kind
of interfaces that are managed by SimMF:
•
•
•
Data flows using basic data type or user defined structures. If the model is a synchronous model
then the data flow exchanges are performed when the model is scheduled using explicit input
updates and output propagations. If the model is an asynchronous model (the ones with a small
lightning icon in the upper left corner) then the data flow exchanges are automatically
performed without any scheduling or explicit activation and this also automatically activates the
connected models computation in a recursive manner.
Software interfaces. A basic software interface, the so-called “Activator”, is defined by default.
It is an interface with a single method without parameter which returns nothing. However,
SimMF users can easily define their own interfaces with arbitrary methods compatible with
C++ and SMP2 standard.
System interfaces of the following types:
o Power line : current and voltage
o Power pulse line : current, voltage and pulse length
o Analog line : to get/set analogic signals
o Digital line : to get/set digital signals
SESP 2012: Simulation and EGSE facilities
for Space Programmes