Download MELSEC-L Serial Communication Module User`s Manual (Basic)
Transcript
15 TROUBLESHOOTING 15.3.16 Communication is not available via the modem Symptom Cause • A modem initialization error occurs. • Auto modem initialization cannot be executed. • Data cannot be communicated with GX Works2 supporting the C24. NonBidirectional procedural Predefined protocol protocol MC NonBidirectional procedural protocol protocol • Check the error code and execute processing accordingly. • There is an error in the switch settings in GX Works2. • Review the switch settings. Set it to match the local station modem and the TA. • Communication protocol setting is incorrect. • Set the communication protocol to MC protocol, Format 5. • Transmission setting does not match the • Review the transmission setting. external device. • Communication rate does not match the • Review the communication rate setting. external device. • The GX Works2 does not • There was an error in the GX Works2 receive the callback connection system. signals from the C24. • When performing Auto (callback: during fixed/ during designated number) from GX Works2, connection to the C24 is refused. MC • Modem connection channel designation • Set Modem connection channel is not performed. designation. • The product is not supported by GX Works2. • Callback connections from GX Works2 are refused by the C24. Corrective action • Confirm the GX Works2 S/W version. • Check the GX Works2 connection system. • Set the connection system on "callback reception waiting" and connect. • There is an error in the GX Works2 side’s modem settings. • Set the modem’s settings on "Auto Reception." • There s an error in the GX Works2 connection system. • Check the GX Works2 connection system. • Correct the C24’s settings. • There is an error in the connection system’s telephone No. • Check the telephone No. • Change the telephone No. to the data for callback. • There is an error in the C24 setting value. • Set the callback function designation on the setting 1 to 3. • There is an error in the GX Works2 connection system. • Check the GX Works2 connection system. • Check the C24’s settings. • Check the telephone No. • There is an error in the telephone No. of • Change the telephone No. to the data the connection system. for callback. • It is possible to connect • The timer value for the status of the from GX Works2, but modem used or the line is short. callback from C24 cannot be performed. • There is a problem with the modem specifications or settings. • Adjust each of the timer values for the callback function on the GX Works2 side. (Line callback cancel wait time, callback delay time) • Check the modem’s specifications and settings. 15.3.17 Communication is not available with the ISDN sub-address Symptom Cause • Sub-address is incorrect. • Data cannot be • Modem does not support ISDN subcommunicated with ISDN address. sub-address • Sub-address is incorrectly partitioned. 15 - 52 Corrective action Predefined • Review the sub-address. • Use modem that supports ISDN subaddress. • Review how to partition the sub-address using the TA manual. 15 - 52