SECTION 9 - LAN INTERFACE [E-Series MODELS ONLY] 9.1 INTRODUCTION KLR Power Supplies may be programmed via the LAN interface using the ports illustrated in Figure 2-1. These ports are described in the following paragraphs. 9.2 USING PORT 80 (WEB INTERFACE) The web interface via port 80 supports up to eight connections to the unit. For details as to how to access, operate and configure the unit using the web interface, refer to the KLR User Manual. 9.3 USING PORT 5024 (TELNET) To access the unit via Telnet port 5024 the proper command line is TELENET IP ADDRESS PORT. e.g.: TELNET 192.168.0.100 5024 NOTE: Port 5025 (SCPI RAW) can also be accessed with the Telnet utility, but the data sent is not echoed back to the user and there is no prompt string. The SCPI-TELNET port transfers ASCII SCPI data using the Control M or Control J characters as line terminators. Table 9-1 lists the Control characters applicable to this port. TABLE 9-1. TELNET PORT 5024 AND SCPI RAW PORT 5025 CONTROL CHARACTERS HEX Name Key Function 1SOH Ctrl A Terminate connection 2STX Ctrl B Execute Trigger, respond with <TRIGGER> 3ETX Ctrl C Execute Device clear to unit respond with <DEVICE CLEAR> Ctrl J or Ctrl M Line Terminator 5 ENQ Ctrl E Unit will respond with the user description of the device. 12DC2 Ctrl R Lock port 14DC4 Ctrl T Unlock Port On receipt of Lock Port, unit verifies other ports (5025 and 1024) are unused and grants the requesting port exclusive access to control KLR. If port lock is unsuccessful, unit responds with <DENIED LOCK>. If successful unit responds with <GRANTED LOCK>. KLR-DEV 060713 9-1