Item FR-A700 series*1 MR-J3(W)-□B Control loop changing command Invalid Valid when using servo amplifier for fully closed loop control (MR-J3-B-RJ006) Servo parameter read/write Unusable Usable Amplifier-less operation function*2 Usable*3 Usable Driver communication Unusable Usable*4 Monitoring of servo parameter error No. Unusable Usable Servo error (Motion error history) Error codes detected by FR-A700 series are stored. Error codes detected by servo amplifier are stored. Programming tool MR Configurator2 is not available. Use FR-DU07/FR-PU07, or FR Configurator. MR Configurator2 is available. *1 *2 *3 For details of FR-A700 series, refer to FR-A700 series instruction manual. During amplifier-less operation function, the following are spuriously connected. Servo amplifier: MR-J3-10B Servo motor: HF-KP053 Parameters set in FR-A700 series are not controlled by Motion CPU. Therefore, the operation is the same as when the servo parameter "Rotation direction selection/travel direction selection (PA14)" is set as below during amplifier-less operation mode. Setting item Setting value Details Rotation direction selection/travel direction selection (PA14) 0 Positioning address increase: CCW or positive direction *4 164 Positioning address decrease: CW of negative direction Refer to the "Servo Amplifier Instruction Manual" for the servo amplifiers that can be used. 5 FUNCTIONS USED WITH SSCNET COMMUNICATION 5.6 Compatible Devices with SSCNETIII(/H)