Item
FR-A700 series*1
MR-J3(W)-□B
Control loop changing command
Invalid
Valid when using servo amplifier for fully closed loop
control (MR-J3-B-RJ006)
Servo parameter read/write
Unusable
Usable
Amplifier-less operation function*2
Usable*3
Usable
Driver communication
Unusable
Usable*4
Monitoring of servo parameter error No.
Unusable
Usable
Servo error (Motion error history)
Error codes detected by FR-A700 series are stored.
Error codes detected by servo amplifier are stored.
Programming tool
MR Configurator2 is not available.
Use FR-DU07/FR-PU07, or FR Configurator.
MR Configurator2 is available.
*1
*2
*3
For details of FR-A700 series, refer to FR-A700 series instruction manual.
During amplifier-less operation function, the following are spuriously connected.
Servo amplifier: MR-J3-10B
Servo motor: HF-KP053
Parameters set in FR-A700 series are not controlled by Motion CPU. Therefore, the operation is the same as when the servo parameter
"Rotation direction selection/travel direction selection (PA14)" is set as below during amplifier-less operation mode.
Setting item
Setting value
Details
Rotation direction selection/travel direction selection
(PA14)
0
Positioning address increase: CCW or positive direction
*4
164
Positioning address decrease: CW of negative direction
Refer to the "Servo Amplifier Instruction Manual" for the servo amplifiers that can be used.
5 FUNCTIONS USED WITH SSCNET COMMUNICATION
5.6 Compatible Devices with SSCNETIII(/H)