Download MELSEC iQ-R Motion Controller Programming Manual (Common)
Transcript
No. Name Meaning Details Set by (When set) SD260 Number of points assigned to bit device X number of points assigned (L) The number of points of the device X currently set is stored as 32-bit data. S (Initial processing) SD261 X number of points assigned (H) SD262 Y number of points assigned (L) SD263 Y number of points assigned (H) SD264 M number of points assigned (L) SD265 M number of points assigned (H) SD266 B number of points assigned (L) SD267 B number of points assigned (H) SD270 F number of points assigned (L) SD271 F number of points assigned (H) SD280 Word device number of points assigned D number of points assigned (L) SD281 D number of points assigned (H) SD282 W number of points assigned (L) SD283 W number of points assigned (H) A The number of points of the device Y currently set is stored as 32-bit data. • The number of points of the device M currently set is stored as 32-bit data. • The number of points assigned is stored even when the number of points assigned to M is 32K points or less. • The number of points of the device B currently set is stored as 32-bit data. • The number of points assigned is stored even when the number of points assigned to B is 32K points or less. The number of points of the device F currently set is stored as 32-bit data. • The number of points of the device D currently set is stored as 32-bit data. • The number of points assigned is stored even when the number of points assigned to D is 32K points or less. SD480 Motion CPU operation cycle over count 0: Motion operation cycle over not occurrence (Normal) 1 to 65535: Operation cycle over cumulative count Stores the count for the motion operation process (including intermodule synchronization process) not completed within the motion operation cycle. After exceeding 65535 the count returns to 0 and counts again. The counts are stored regardless of the "CPU module operation setting at error detected" RAS setting. This counter is valid even is inter-module synchronization is not used. SD484 Fixed scan data transmission section over count 0: Fixed scan data transmission section over not occurrence (Normal) 1 to 65535: Fixed scan data transmission section over cumulative count Stores the count for the motion operation process not completed by the fixed-cycle data transmission set in the Multiple CPU synchronous cycle. After exceeding 65535 the count returns to 0 and counts again. The counts are stored regardless of the "CPU module operation setting at error detected" RAS setting. This counter is valid even is inter-module synchronization is not used. S (Change status) APPENDICES APPENDIX Appendix 4 Special Registers 309