Download Untitled - Oasys Software

Transcript
Oasys LS-DYNA Environment Software
Section 4 – Oasys T/HIS: Bugs fixed in version 9.3
• Case 11400
In T/HIS 9.3 RC1 and RC2 curves were plotted incorrectly if both the X and Y axes were set to log
scales. As well as the curves being drawn incorrectly symbols and the cross from the 'point'
function would be drawn in the wrong position. This has been fixed in 9.3.
• Case 11382
In T/HIS 9.3 RC2 T/HIS could get stuck in an infinite loop if a MACRO function was run that
required a single curve as input but multiple curves were specified for the input (so that the
MACRO is run multiple times). This has been fixed in version 9.3.
• Case 11381
In T/HIS 9.3 RC1 and RC2 multiple 'zoom' boxes could be displayed in graphics area if a zoom
operation was started and the mouse was released outside of the graphics box. These problems
have been resolved in 9.3.
• Case 11313
In T/HIS 9.3 RC2 T/HIS could apply the wrong label to curves if multiple contact forces were read
from the LSDA file in one go. This would only occur if the contacts in the RCFORC file were not
listed in increasing ID order. If the force from a single contact was read then the labels would be
correct.
• Case 11295
In T/HIS 9.3 RC1 and RC2 the axis values were not updated correctly if dynamic viewing was used
to translate a curve while one or more of the axes were displaying a logarithmic scale. This has
been fixed in 9.3.
• Case 11259
In T/HIS 9.3 RC1 and RC2 the 'All Active Graphs' button in the Images menu actually selected all
graphs for output and 'All Graphs' button selected all the active graphs. This has been fixed in 9.3.
• Case 11255
In T/HIS 9.3 RC1 and RC2 the directory names displayed when the option to search directories
recursively could get corrupted if the user entered the search path as '.' and then used one of the
file selector buttons in another menu. This has been fixed in 9.3
• Case 11106
Versions of T/HIS prior to 9.3 would not read RWFORC files which contained 'per segment' force
data. T/HIS 9.3 will now read the total forces for each wall correctly but it will ignore the 'per
segment' data.
• Case 11098
In T/HIS 9.3 RC1 and RC2 the 6 user defined lines that can be added to the bottom right hand
corner of the legend area were not being stored correctly for each graph and one set was being
used for all graphs. This has been fixed in version 9.3 so that the data is stored individually for
each graph.
• Case 11091
In T/HIS 9.3 RC1 and RC2 curves were not added correctly to graphs in FAST-TCF scripts if the
image output option was turned off. This has been fixed in 9.3 so that the curves and graphs are
setup correctly regardless of the image output option.
• Case 11043
In T/HIS 9.3 RC2 the FAST-TCF command 'operate com' would not playback correctly if the 2 input
curves were referenced via curve tags (curve numbers would work). This has been fixed in 9.3.
• Case 11035
T/HIS 9.3 can now read the 'frictional energy' data component from both the SLEOUT ASCII file
and the BINOUT file.
Ove Arup & Partners Ltd
th
30 August 2008
Pg. 116
Oasys Suite v9.3
Release Notes