Download User Manual - Excalibur Engineering
Transcript
Capturing Data In The Trace Memory Capture Mode NOTE If the Analyzer is set up to fill the trace memory after a trigger event and the event does not occur, stopping the Analyzer sets an artificial triggerpoint. The trace memory will then contain 100 % pre-trigger history. The last captured state is the state before the Analyzer has been stopped. Nevertheless, the trace memory can still be empty if no samples were taken because of the storage qualification. Capture Mode The availability of the sequencer depends on the selected capture mode. The Agilent E2925B testcard provides the following modes for capture control: • Standard In the standard mode, the trace memory trigger and storage qualifier are directly controlled by pattern terms. Pattern terms are programmable pattern recognizes. If the programmed pattern is found on the bus, the pattern term signals – the trigger to initiate the sampling, or – the storage qualifier to capture the current sample. • Sequencer In the sequencer mode, the trigger sequencer controls the trace memory’s trigger and storage qualifier. The sequencer detects sequences of patterns. To detect the patterns, it uses pattern terms as input. Each state of the sequence can be used to control the sequencer’s output, trigger and storage qualifier. • Performance The performance mode is only available if the PCI Optimizer (option #200) has been installed. In the performance mode, the storage qualifier is automatically programmed as required for performance measurements. A trigger can be set up to start the measurement. 74 Agilent E2925B PCI Analyzer User’s Guide, August 2002