Download User Manual - Excalibur Engineering

Transcript
Analyzing PCI Performance
Sample Advanced Performance Setup
Sample Advanced Performance
Setup
To explain how to program an advanced performance measure, an
example shows how to measure the proportion of non-idle cycles in PCI
traffic.
The required sequencer setup is quite simple. It uses the pattern term
pt4 as follows:
• pt4: b_state=Idle
This makes pattern term pt4 sensitive to idle cycles.
The sequencer of performance measure 1 is programmed to remain in
state 0 only, incrementing counter A and B if their enable conditions are
true:
• Counter A must be incremented with each non-idle cycle. Therefore,
pattern term pt4 must be inverted.
• Counter B must be incremented with each clock cycle.
The sequencer description table must be set up as follows:
Table 3
NOTE
66
Sample Sequencer Description Table
State
Next State
Transition
Condition
Counter A
Enable
Condition
(Output)
0
0
1
!pt4
Counter B
Enable
Condition
(Output)
1
In the table above, only those columns are shown that need to be
programmed for the example.
Agilent E2925B PCI Analyzer User’s Guide, August 2002