<1. Introduction>
1.Introduction
Website address: http://www.yokogawa.com/fld/doc/
Table 1.1 Manual List
Model
AXFG
AXFC
AXFH
AXFW
AXFA11G
AXFA14G
AXFA14C
Document Title
AXF Magnetic Flowmeter Integral Flowmeter/
Remote Flowtube [Hardware Edition]
AXFA14G/C Magnetic Flowmeter Remote
Converter
[Hardware Edition/Software Edition]
AXF Magnetic Flowmeter Integral Flowmeter
[Software Edition]
AXFA11G Magnetic Flowmeter Remote
Converter
[Hardware Edition/Software Edition]
AXFA14G/C Magnetic Flowmeter Remote
Converter
[Hardware Edition/Software Edition]
AXF Magnetic Flowmeter Integral Flowmeter
[Software Edition]
Document No.
IM 01E20D01-01E
IM 01E20C02-01E
IM 01E20C01-01E
IM 01E20C02-01E
In case of selecting the communication code (The first
two characters of suffix code) “-F”, further refer to the
following manual.
Model
Communication
Code
AXFG
AXFC
AXFH
-F
AXFW
AXFA14G
AXFA14C
Document Title
Document No.
ADMAG AXF Series
FOUNDATION Fieldbus
IM 01E20F02-01E
Communication Type
Magnetic Flowmeter
In case of selecting the communication code (The first
two characters of suffix code) “-G”, further refer to the
following manual.
Model
Communication
Code
AXFG
AXFC
AXFH
-G
AXFW
AXFA14G
AXFA14C
Document Title
Document No.
AXF PROFIBUS PA
Communication Type IM 01E20F12-01E
Magnetic Flowmeter
NOTE
For FOUNDATION fieldbus protocol, or PROFIBUS PA
protocol, refer to IM 01E20A01-02EN. For HART
protocol, refer to the applicable user’s manuals which
can be downloaded from our website.
NOTE
When describing the model name like AXFC in
this manual, “” means any of the following.
002, 005, 010, 015, 025, 032, 040, 050, 065, 080, 100,
125, 150, 200, 250, 300, 350, 400
 Safety and Modification Precautions
• The following general safety precautions must be
observed during all phases of operation, service,
and repair of this instrument. Failure to comply with
these precautions or with specific WARNINGS given
elsewhere in this manual violates safety standards
of design, manufacture, and intended use of the
instrument. Yokogawa assumes no liability for the
customer’s failure to comply with these requirements.
If this instrument is used in a manner not specified in
this manual, the protection provided by this instrument
may be impaired.
• Yokogawa will not be liable for malfunctions or
damage resulting from any modification made to this
instrument by the customer.
• The following safety symbol marks are used in this
user’s manual and instrument.
WARNING
A WARNING sign denotes a hazard. It calls attention
to procedure, practice, condition or the like, which, if
not correctly performed or adhered to, could result in
injury or death of personnel.
CAUTION
A CAUTION sign denotes a hazard. It calls attention
to procedure, practice, condition or the like, which, if
not correctly performed or adhered to, could result in
damage to or destruction of part or all of the product.
Note: “” means any of the following.
002, 005, 010, 015, 025, 032, 040, 050, 065, 080, 100,
125, 150, 200, 250, 300, 350, 400
2nd Edition: Aug. 2015 (KP)
All Rights Reserved, Copyright © 2014, Yokogawa Electric Corporation
IM 01E20A01-01EN
1
Introduction
Thank you for purchasing the ADMAG AXF Magnetic
flowmeter.
This manual provides the basic guidelines for installation
and wiring procedures of integral flowmeter, remote
flowtube, and remote converter of the AXF magnetic
flowmeters through front panel, BRAIN protocol, and
HART protocol.
It does not provide the product specific functional
specifications and explanations, maintenance,
troubleshooting, FOUNDATION fieldbus and PROFIBUS
PA communication operating procedures. For the items
which are not covered in this manual, see the applicable
user’s manuals as listed in Table 1.1. These manuals
can be downloaded from the website of Yokogawa. To
ensure correct use of the instrument, read these manuals
thoroughly and fully understand how to operate the
instrument before operating it. For method of checking
the model and suffix code, refer to Section 2.1.