Download User`s Manual
Transcript
1 <1. Introduction> 1.Introduction Website address: http://www.yokogawa.com/fld/doc/ Table 1.1 Manual List Model AXFG AXFC AXFH AXFW AXFA11G AXFA14G AXFA14C Document Title AXF Magnetic Flowmeter Integral Flowmeter/ Remote Flowtube [Hardware Edition] AXFA14G/C Magnetic Flowmeter Remote Converter [Hardware Edition/Software Edition] AXF Magnetic Flowmeter Integral Flowmeter [Software Edition] AXFA11G Magnetic Flowmeter Remote Converter [Hardware Edition/Software Edition] AXFA14G/C Magnetic Flowmeter Remote Converter [Hardware Edition/Software Edition] AXF Magnetic Flowmeter Integral Flowmeter [Software Edition] Document No. IM 01E20D01-01E IM 01E20C02-01E IM 01E20C01-01E IM 01E20C02-01E In case of selecting the communication code (The first two characters of suffix code) “-F”, further refer to the following manual. Model Communication Code AXFG AXFC AXFH -F AXFW AXFA14G AXFA14C Document Title Document No. ADMAG AXF Series FOUNDATION Fieldbus IM 01E20F02-01E Communication Type Magnetic Flowmeter In case of selecting the communication code (The first two characters of suffix code) “-G”, further refer to the following manual. Model Communication Code AXFG AXFC AXFH -G AXFW AXFA14G AXFA14C Document Title Document No. AXF PROFIBUS PA Communication Type IM 01E20F12-01E Magnetic Flowmeter NOTE For FOUNDATION fieldbus protocol, or PROFIBUS PA protocol, refer to IM 01E20A01-02EN. For HART protocol, refer to the applicable user’s manuals which can be downloaded from our website. NOTE When describing the model name like AXFC in this manual, “” means any of the following. 002, 005, 010, 015, 025, 032, 040, 050, 065, 080, 100, 125, 150, 200, 250, 300, 350, 400 Safety and Modification Precautions • The following general safety precautions must be observed during all phases of operation, service, and repair of this instrument. Failure to comply with these precautions or with specific WARNINGS given elsewhere in this manual violates safety standards of design, manufacture, and intended use of the instrument. Yokogawa assumes no liability for the customer’s failure to comply with these requirements. If this instrument is used in a manner not specified in this manual, the protection provided by this instrument may be impaired. • Yokogawa will not be liable for malfunctions or damage resulting from any modification made to this instrument by the customer. • The following safety symbol marks are used in this user’s manual and instrument. WARNING A WARNING sign denotes a hazard. It calls attention to procedure, practice, condition or the like, which, if not correctly performed or adhered to, could result in injury or death of personnel. CAUTION A CAUTION sign denotes a hazard. It calls attention to procedure, practice, condition or the like, which, if not correctly performed or adhered to, could result in damage to or destruction of part or all of the product. Note: “” means any of the following. 002, 005, 010, 015, 025, 032, 040, 050, 065, 080, 100, 125, 150, 200, 250, 300, 350, 400 2nd Edition: Aug. 2015 (KP) All Rights Reserved, Copyright © 2014, Yokogawa Electric Corporation IM 01E20A01-01EN 1 Introduction Thank you for purchasing the ADMAG AXF Magnetic flowmeter. This manual provides the basic guidelines for installation and wiring procedures of integral flowmeter, remote flowtube, and remote converter of the AXF magnetic flowmeters through front panel, BRAIN protocol, and HART protocol. It does not provide the product specific functional specifications and explanations, maintenance, troubleshooting, FOUNDATION fieldbus and PROFIBUS PA communication operating procedures. For the items which are not covered in this manual, see the applicable user’s manuals as listed in Table 1.1. These manuals can be downloaded from the website of Yokogawa. To ensure correct use of the instrument, read these manuals thoroughly and fully understand how to operate the instrument before operating it. For method of checking the model and suffix code, refer to Section 2.1.