Download User`s Manual
Transcript
83 <10. Explosion Protected Type Instrument> 10.2FM (1) Technical Data (AXF Integral Flowmeter), (AXF Remote Flowtube) Applicable Standard: FM3600, FM3610, FM3615, FM3810, ANSI/NEMA 250 (AXF Integral Flowmeter) Explosion proof for Class I, Division 1, Groups A, B, C & D. Dust-ignition proof for Class II/III, Division1, Groups E, F & G. Intrinsically safe (electrodes) for Class I, Division 1, Groups A, B, C & D. “SEAL ALL CONDUITS WITHIN 18 INCHES” “WHEN INSTALLED IN DIV. 2, SEALS NOT REQUIRED” Electrode Circuit Um: 250 Vac/dc Maximum power supply voltage: 250 Vac/130 Vdc Excitation Circuit: 140V max Enclosure: NEMA 4X Temperature Code: T6 (AXFA14 Remote Converter) Applicable Standard: FM3600, FM3615, FM3810, ANSI/NEMA 250 Explosion proof for Class I, Division 1, Groups A, B, C & D. Dust-ignition proof for Class II/III, Division 1, Groups E, F & G. “SEAL ALL CONDUITS WITHIN 18 INCHES” “WHEN INSTALLED IN DIV. 2, SEALS NOT REQUIRED” Maximum power supply voltage: 250 Vac/130 Vdc Excitation Circuit: 140V max Enclosure: NEMA 4X Temperature Code: T6 Ambient Temp.: –40°C to +60°C (–40°F to +140°F) (2) Electrical Connection The type of electrical connection is stamped near the electrical connection port according to the following codes. (AXF Integral Flowmeter) Screw Size Marking ISO M20x1.5 female M ANSI 1/2NPT female N Note: Temperature Code T5 to T3 included in the scope of application and its approval Refer to following table; Temperature Code T6 T5 T4 T3 Maximum Process Temperature +70°C (+158F) +85°C (+185F) +120°C (+248F) +130°C (+266F) Minimum Process Temperature –40°C (–40°F) –40°C (–40°F) –40°C (–40°F) –40°C (–40°F) Ambient Temp.: –40°C to +60°C (–40°F to +140°F) (AXF Remote Flowtube) Explosion proof for Class I, Division 1, Groups A, B, C & D. Dust-ignition proof for Class II/III, Division1, Groups E, F & G. Intrinsically safe (electrodes) for Class I, Division 1, Groups A, B, C & D. “SEAL ALL CONDUITS WITHIN 18 INCHES” “WHEN INSTALLED IN DIV. 2, SEALS NOT REQUIRED” Electrode Circuit Um: 250 Vac/dc Excitation Circuit: 170V max Enclosure: NEMA 4X Temperature Code: T6 (AXF Remote Flowtube) Screw Size Marking ISO M20x1.5 female M ANSI 1/2NPT female N F1009.ai (AXFA14 Remote Converter) Screw Size Marking ISO M20x1.5 female M ANSI 1/2NPT female N 10 Explosion Protected Type Instrument Note: Temperature Code T5 to T3 included in the scope of application and its approval Refer to following table; Temperature Code T6 T5 T4 T3 Maximum Process Temperature +70°C (+158°F) +85°C (+185°F) +120°C (+248°F) +150°C (+302°F) Minimum Process Temperature –40°C (–40°F) –40°C (–40°F) –40°C (–40°F) –40°C (–40°F) F1010.ai Ambient Temp.: –40°C to +60°C (–40°F to +140°F) IM 01E20A01-01EN