MCR Temperature Measuring Transducer – MCR-T-UI(-E)...
Output
Output signal
Maximum output signal
D/A resolution
Load
Ripple
Open-circuit response
Measuring range exceeded/not reached
Output protection
Switching output
General Data
Supply voltage
Current consumption
Transmission error
Cold junction error
Temperature coefficient
Ambient temperature range
Test voltage (only MCR-T-UI-E...)
0…20 mA 4…20 mA 0(1)…5 V 0…10 V ± 5 V
± 10 V
24 mA
24 mA
±12 V
±12 V ±12 V ± 12 V
± 12 bits
≤ 500 Ω ≤ 500 Ω ≥ 10 kΩ ≥ 10 kΩ ≥ 10 kΩ ≥ 10 kΩ
< 20 mVpp
From - 12 V to + 12 V or 0 mA to 24 mA
From - 12 V to + 12 V or 0 mA to 24 mA
Transient protection
PNP transistor output, with a load capacity of 100 mA, switches supply
voltage; disabled for project-specific configuration, otherwise can be
freely programmed using MCR-CONF-WIN-... and MCR/PI-CONFWIN.
Input/output
Input/power supply
Approbation
c
18...30 V DC
≤ 60 mA
≤ 0.1% of the final value, + 6 mV or 12 µA at the output
≤ 3 K, typical 1.5 K
≤ 0.01%/K, typical 0.005%/K
- 20°C to + 65°C (-4˚F to 149˚F)
1 kV, 50 Hz, 1 minute
1 kV, 50 Hz, 1 minute
F
Conforms to the EMC Directive 89/336/EEC and the
Low Voltage Directive 73/23/EEC
EMC (electromagnetic compatibility)
Noise immunity according to 50082-2
• Electrostatic discharge (ESD)
8 kV air discharge2)
4 kV contact discharge2)
EN 61000-4-2
• Electromagnetic HF field
Amplitude modulation
Pulse modulation
EN 61000-4-3
• Fast transients (burst)
EN 61000-4-4
Input/output/supply:
2 kV/5 kHz2)
• Conducted interference
EN 61000-4-6
Input/output/supply:
10 V1)
Noise emission according to EN 50081-2
EN 55011
Class A
EN 61000 corresponds to IEC 1000/
EN 55011 corresponds to CISPR22
These results were achieved using shielded cables.
1)
2)
10 V/m1)
10 V/m1)
Criterion A: normal operating characteristics within the specified
limits.
Criterion B: temporary adverse effects on the operating
characteristics which the device corrects itself.
Class A:
industrial application without special
installation measures
1
6
O
4V
P
+2
I
U
R ND
E G
WP
D
S T GN
U
O
I
T/U
RMC
2
r
we
Po
de
Mo
1
2
4
IN
MCR-T-UI ... MCR Temperature Measuring
Transducer
N
3
C
N
C
1 Programming interface
1
0
I 4 09
T/U 1
R- : 28
MC.-Nr.
Art
7
T
OU
2
3
8
2 Plug-in screw-clamp terminals (COMBICON)
D A
3
3 Shield connection (on terminal 5 or 6)
5
IN
6
ϑ
2
=
4
5
6
4 Metal lock for fastening on the DIN rail
1
2
3
6 Error LED
11
12
D
1
3
5 Plug-in screw-clamp terminals (COMBICON)
9
10
µC
4
4
.
/
N.C
N
.
NE
N.C ATIO
6
OB
PR
AP
=
7
I
8
T
OU
U
T
9
OU
10
D
DC
GN
V
11
4
+2
12
SP
D
GN
LS
A
OV
PR
AP
5
4
PHOENIX CONTACT page 3 of 7
5