Download Manual
Transcript
MCR Temperature Measuring Transducer – MCR-T-UI(-E)... Output Output signal Maximum output signal D/A resolution Load Ripple Open-circuit response Measuring range exceeded/not reached Output protection Switching output General Data Supply voltage Current consumption Transmission error Cold junction error Temperature coefficient Ambient temperature range Test voltage (only MCR-T-UI-E...) 0…20 mA 4…20 mA 0(1)…5 V 0…10 V ± 5 V ± 10 V 24 mA 24 mA ±12 V ±12 V ±12 V ± 12 V ± 12 bits ≤ 500 Ω ≤ 500 Ω ≥ 10 kΩ ≥ 10 kΩ ≥ 10 kΩ ≥ 10 kΩ < 20 mVpp From - 12 V to + 12 V or 0 mA to 24 mA From - 12 V to + 12 V or 0 mA to 24 mA Transient protection PNP transistor output, with a load capacity of 100 mA, switches supply voltage; disabled for project-specific configuration, otherwise can be freely programmed using MCR-CONF-WIN-... and MCR/PI-CONFWIN. Input/output Input/power supply Approbation c 18...30 V DC ≤ 60 mA ≤ 0.1% of the final value, + 6 mV or 12 µA at the output ≤ 3 K, typical 1.5 K ≤ 0.01%/K, typical 0.005%/K - 20°C to + 65°C (-4˚F to 149˚F) 1 kV, 50 Hz, 1 minute 1 kV, 50 Hz, 1 minute F Conforms to the EMC Directive 89/336/EEC and the Low Voltage Directive 73/23/EEC EMC (electromagnetic compatibility) Noise immunity according to 50082-2 • Electrostatic discharge (ESD) 8 kV air discharge2) 4 kV contact discharge2) EN 61000-4-2 • Electromagnetic HF field Amplitude modulation Pulse modulation EN 61000-4-3 • Fast transients (burst) EN 61000-4-4 Input/output/supply: 2 kV/5 kHz2) • Conducted interference EN 61000-4-6 Input/output/supply: 10 V1) Noise emission according to EN 50081-2 EN 55011 Class A EN 61000 corresponds to IEC 1000/ EN 55011 corresponds to CISPR22 These results were achieved using shielded cables. 1) 2) 10 V/m1) 10 V/m1) Criterion A: normal operating characteristics within the specified limits. Criterion B: temporary adverse effects on the operating characteristics which the device corrects itself. Class A: industrial application without special installation measures 1 6 O 4V P +2 I U R ND E G WP D S T GN U O I T/U RMC 2 r we Po de Mo 1 2 4 IN MCR-T-UI ... MCR Temperature Measuring Transducer N 3 C N C 1 Programming interface 1 0 I 4 09 T/U 1 R- : 28 MC.-Nr. Art 7 T OU 2 3 8 2 Plug-in screw-clamp terminals (COMBICON) D A 3 3 Shield connection (on terminal 5 or 6) 5 IN 6 ϑ 2 = 4 5 6 4 Metal lock for fastening on the DIN rail 1 2 3 6 Error LED 11 12 D 1 3 5 Plug-in screw-clamp terminals (COMBICON) 9 10 µC 4 4 . / N.C N . NE N.C ATIO 6 OB PR AP = 7 I 8 T OU U T 9 OU 10 D DC GN V 11 4 +2 12 SP D GN LS A OV PR AP 5 4 PHOENIX CONTACT page 3 of 7 5