4.13 PTP - Precision Time Protocol
4.13.6 ptp clock-mode
Configure the Precision Time Protocol (PTP, IEEE 1588) clock mode. If the
clock mode is changed, PTP will be initialized. The default is "disable“
Format
ptp clock-mode {boundary-clock|simple-mode}
Mode
Global Config
4.13.7 ptp operation
Enable or disable the Precision Time Protocol (IEEE 1588).
The default is "False“
Format
operation {disable|enable}
Mode
Global Config
4.13.8 ptp preferred-master
Specify if the local switch shall be regarded as a preferred master clock (i. e.,
if it will remain master in the presence of disconnection or connection of other
clocks).
Format
preferred-master {false|true}
Mode
Global Config