Download ST950 FACILITIES HANDBOOK
Transcript
Mobility Division, Traffic Solutions Sopers Lane, Poole, Dorset, BH17 7ER The timing range is 0 to 255 seconds in 1-second steps with one time for the whole controller. 9.5.9 Conditioning Timers (PIR, CDT) Up to 480 conditioning timers (numbered 0 to 479) are available for use as auxiliary timers. The uses of the conditioning timers include the following: Holding a stage for a specified fixed period when no phases gain ROW, e.g. the all-red stage. Normally dummy phases are used for this purpose, but this method may be used if no dummy phases are available. Timing long periods - can be achieved by running the same timer several times, e.g. to time 20 minutes, give the timer a value of 20 and run it 60 times. Switched window timers. Limit Green watchdog timer. Hurry Call watchdog timer. The timing range for each timer can be configured as either 0 to 255 seconds in 1second steps or 0.0 to 31.8 in 0.2 second steps. NOTE: 480 timers requires ST950 software version 46059 issue 5 or later. Prior to this, only 96 timers were supported. 9.5.10 Limit Green Watchdog (Facility constructed in Special Conditioning for Non UK Only) In all modes except Hurry Call, Vehicle Actuated and Manual Control, the maximum duration of each stage green can be governed by a limit green watchdog time. One limit green watchdog timer (a Special Conditioning timer) is provided, which is applied to each stage in turn. The stage limit green watchdog timer commences timing when the stage green is reached and is reset on a plan change, a mode change and when the stage terminates. If the limit green override code is sent from the ATC computer during computer stage control mode, the limit green watchdog timer is held reset. In the event of a limit green watchdog timer timing out before its associated phase green has terminated, the controller will then revert to the next highest priority mode configured for which a request exists and the fault will be logged. If the current mode at the time of failure is fixed time mode, the controller switches off the power to the lamps. Security classification Unrestricted Version 4 Last Editor Paul Cox Document Name ST950 Facilities Handbook Copyright © Siemens plc 2015. All Rights Reserved. Page 56 of 303 Status Issued Date 16-Jul-2015 Document No. 667/HB/46000/001 Mobility is a division of Siemens Plc