Download - Service, Support
Transcript
4. Press this button on the main screen of SinuComPCIN and select the desired program for execution, for example, Test.mpf. The program is transferred to the buffer memory on the control system and then displayed in the following window: 5. If desired, you can use this softkey to specify how you want the program to be executed (for more information of the program control, refer to Section "Program control (Page 39)") . 6. Press this key to execute the program. The program is reloaded continuously. Either at the end of the program or after pressing the following key, the program is automatically removed from the control system: Note When using the external execution via RS232, the RS232 interface must not be active for another application. This means, for example, the RS232 interface must not be active through the following operation: + 6.5.1.3 → "PLC" → . Transferring from external (through RS232 interface) Prerequisites: ● The tool SinuComPCIN has been installed on your PC. ● The RS232 communication has been successfully established between the control system and the PC. Note The program files can be transferred only to the system drive N:\MPF or N:\CMA; therefore, before transfer make sure the drive identifier contained in the first line in the program file is "N" and the target directory in the second line is "N_MPF" or "N_CMA". If not, you must change manually, for example: 44 Programming and Operating Manual (Turning) 6FC5398-5DP10-0BA3, 08/2015