DREAM Chapter 3. Operating the DREAM Program 3-1 3. OPERATING THE DREAM PROGRAM The DREAM program is used to provide the user of Sentinel the means for automatic diagnostics and condition prediction of rotating machinery. The operation with DREAM can be divided into three main stages: preliminary configuration of DREAM and Sentinel databases, field measurements and condition diagnostics. 3.1. CONFIGURATION During its operation DREAM uses two databases: the one of Sentinel where the names of measurement points, their hierarchy and corresponding spectra are stored and its own database where DREAM stores additional parameters of the equipment to be diagnosed that it needs as an expert system. The configuration process - it means to set up all the required parameters of your equipment and measurements - should be done in both Sentinel and DREAM databases. First of all make sure that all necessary measurement points are configured in the Sentinel database. Then, before starting DREAM exit Sentinel software. Start DREAM program, choose the Open command from the DataBase menu. DREAM will open the database of Sentinel and read all the plants' structure. After this DREAM will display in its main window the names of all the plants from the Sentinel database: Fig. 3.1. Main window of the DREAM software with the names of the plants configured in the Sentinel database. To display the names of the areas that belong to a plant, double-click its name. The same way you can open the units, machines and measurement points.