Download Cabinet Model Instructions

Transcript
GENERAL INCUBATOR OPERATING INSTRUCTIONS FOR SEVERAL SPECIES OF BIRDS
Bobwhite
Quail
Requirements
Incubation period (days) 23-24
Temperature (F)
Cotumix
Quail
Ostrich
17
42-48
Emu
Duck
43-50
100
100
84-86
84-86
70
70
Final day of egg rotation
21
15
38-40
44-46
Temperature during final 3
days of incubation (F)
99.5
99.5
96-96.5 96-96.5
Humidity during final 3 days
90-94
of incubation (wet bulb, F)
90-94
Humidity (wet bulb, F)*
Duck Muscovy Goose Guinea Pheasant Peafowl Chicken, Turkey Chukar
Rheas
35-40
28
35-37
28-34
28
23-28
28-30
100
100
100
100
100
84-86
84-86
86-88
83-85
82-84
83-85
30-33
25
31
25
25
21
25
19
98.5
99.5
99.5
99.5
99
99.5
99.5
90-94
90-94
90-94
90-94
92-95
90-94
96.5-97 96.5-97 96.5-97 100
75
75
Bantam
85-87
88-90
* % Weight loss: Total weight loss from beginning to end of Incubation should be 12%-15% for morst eggs
% Weight Loss = Original wt. - Present wt. x 100%
Average Daily Wt. =
Original wt.
Loss Required
Timer Motor
with switch
No. 3023
Swing Arm No. 3028
Sw
in
Arm g
Ca
m
Timer Cam
Drive Motor
No. 3022
W
E
T
Side
Mounting
Bracket
Mounting Screw
Side
Mounting
Bracket
B
U
L
B
Set Screw
Side View
Foot for mounting to
fan shelf
25
17
21
28
23-24
100
100
100
100
100
80-82
82-86
84-86
25
21
22
15
99.5
99.5
99.5
99.5
99.5
90-94
90-94
90-94
90-94
90-94
85-87 83-85
Original wt. X .14 (Based on 14% total loss)
Incubation Period
DRY BULB TEMPERATURES
Toggle Switch No. 3025
Switch for Drive
Motor No. 3024
Pigeon
CONVERSION OF WET/DRY BULB READINGS TO PERCENT OF
RELATIVE HUMIDITY
Diagram of incubator turner.
Complete turner is item No. 3021
Timer Motor with switch No. 3023
Grouse
Partridge
View from rear
of incubator
T*
E
M
P
E
R
A
T
U
R
E
S
TURNER PROBLEM CHECK LIST
PROBLEM
CHECK FOR:
Turner fails to turn
1—TEST FOR ASSURANCE THAT TURNER IS WORKING as shown on
automatically
Page 1 of Incubator Instructions.
but will turn manually.
2—Remove back of incubator. DO NOT TOUCH ANY PART OF TURNER
WHILE INCUBATOR OR TURNER IS PLUGGED INTO POWER. Check
to see if turner light comes on when switched to Automatic. If not, check for
loose wires or connections at toggle and other switches. Check all slip on
connections for good contact. If Timer Cam marks do not show signs of rotating in 30 minutes or if Timer Switch seems defective, No. 3023 Timer with
Switch will need to be replaced.
Turner fails to turn
1—Check to be sure trays inside have not been pushed all the way to back
on manual or automatic
or some other obstruction that has jammed the trays.
2—Be sure incubator and turner is plugged into outlet that has electric
current and that pilot light is on when switched to automatic.
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
93
91
92
93
94
95
85
90
95
96
97
98
99
100
101
102
41
44
47
50
33
56
60
63
66
70
73
77
80
84
80
92
96
100
31
34
36
39
41
44
47
50
53
55
58
62
65
68
71
74
78
81
85
89
92
96
100
23
25
28
30
32
34
37
39
42
44
47
49
52
35
57
60
63
66
69
72
76
79
82
86
89
93
96
100
22
24
26
28
30
33
35
37
40
42
45
47
50
32
55
58
61
64
67
70
73
76
79
82
86
89
93
96
21
23
25
27
29
31
33
36
38
40
43
45
48
50
53
55
58
61
64
67
70
73
76
79
83
86
89
93
19
2.1
23
25
27
30
32
34
36
38
41
43
46
4
51
53
56
39
61
64
67
70
73
76
79
83
86
89
18
20
22
24
26
23
30
32
34
37
39
41
44
46
48
51
54
56
59
62
65
67
70
73
76
80
83
86
17
19
21
23
25
27
29
31
33
35
37
39
42
44
46
49
51
54
57
59
62
65
68
71
74
77
80
83
16
18
20
21
23
25
27
29
31
33
36
38
40
42
43
47
49
52
54
57
60
62
63
68
71
74
77
80
15
17
18
20
22
24
26
28
30
32
34
36
38
40
43
43
47
50
52
55
57
60
63
65
68
71
74
77
3—Remove back of incubator. DO NOT TOUCH ANY PART OF
NOTE: The above chart is for sea level readings. A general rule of adjustment
would be to add 1 to the percent value shown in the body of the chart for
each 2500 feet of elevation above sea level.
TURNER WHILE INCUBATOR IS PLUGGED INTO POWER. Check for
loose wires, loose connection rods or jammed tray.
Turns constantly when
1—Switch for Drive Motor is loose and has moved away from Swing Arm
switched
Cam. Loosen screws holding Switch, push switch closer to Cam and while
to automatic
holding it closer to Cam, tighten screws. Avoid over tightening as you
*To obtain lower wet bulb readings, recommended for ratite eggs, we
recommend using an inexpensive room dehumidifier, available at Sears,
WW Grainger and other outlets.
could break switch housing.
5