Download Cabinet Model Instructions
Transcript
GENERAL INCUBATOR OPERATING INSTRUCTIONS FOR SEVERAL SPECIES OF BIRDS Bobwhite Quail Requirements Incubation period (days) 23-24 Temperature (F) Cotumix Quail Ostrich 17 42-48 Emu Duck 43-50 100 100 84-86 84-86 70 70 Final day of egg rotation 21 15 38-40 44-46 Temperature during final 3 days of incubation (F) 99.5 99.5 96-96.5 96-96.5 Humidity during final 3 days 90-94 of incubation (wet bulb, F) 90-94 Humidity (wet bulb, F)* Duck Muscovy Goose Guinea Pheasant Peafowl Chicken, Turkey Chukar Rheas 35-40 28 35-37 28-34 28 23-28 28-30 100 100 100 100 100 84-86 84-86 86-88 83-85 82-84 83-85 30-33 25 31 25 25 21 25 19 98.5 99.5 99.5 99.5 99 99.5 99.5 90-94 90-94 90-94 90-94 92-95 90-94 96.5-97 96.5-97 96.5-97 100 75 75 Bantam 85-87 88-90 * % Weight loss: Total weight loss from beginning to end of Incubation should be 12%-15% for morst eggs % Weight Loss = Original wt. - Present wt. x 100% Average Daily Wt. = Original wt. Loss Required Timer Motor with switch No. 3023 Swing Arm No. 3028 Sw in Arm g Ca m Timer Cam Drive Motor No. 3022 W E T Side Mounting Bracket Mounting Screw Side Mounting Bracket B U L B Set Screw Side View Foot for mounting to fan shelf 25 17 21 28 23-24 100 100 100 100 100 80-82 82-86 84-86 25 21 22 15 99.5 99.5 99.5 99.5 99.5 90-94 90-94 90-94 90-94 90-94 85-87 83-85 Original wt. X .14 (Based on 14% total loss) Incubation Period DRY BULB TEMPERATURES Toggle Switch No. 3025 Switch for Drive Motor No. 3024 Pigeon CONVERSION OF WET/DRY BULB READINGS TO PERCENT OF RELATIVE HUMIDITY Diagram of incubator turner. Complete turner is item No. 3021 Timer Motor with switch No. 3023 Grouse Partridge View from rear of incubator T* E M P E R A T U R E S TURNER PROBLEM CHECK LIST PROBLEM CHECK FOR: Turner fails to turn 1—TEST FOR ASSURANCE THAT TURNER IS WORKING as shown on automatically Page 1 of Incubator Instructions. but will turn manually. 2—Remove back of incubator. DO NOT TOUCH ANY PART OF TURNER WHILE INCUBATOR OR TURNER IS PLUGGED INTO POWER. Check to see if turner light comes on when switched to Automatic. If not, check for loose wires or connections at toggle and other switches. Check all slip on connections for good contact. If Timer Cam marks do not show signs of rotating in 30 minutes or if Timer Switch seems defective, No. 3023 Timer with Switch will need to be replaced. Turner fails to turn 1—Check to be sure trays inside have not been pushed all the way to back on manual or automatic or some other obstruction that has jammed the trays. 2—Be sure incubator and turner is plugged into outlet that has electric current and that pilot light is on when switched to automatic. 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 93 91 92 93 94 95 85 90 95 96 97 98 99 100 101 102 41 44 47 50 33 56 60 63 66 70 73 77 80 84 80 92 96 100 31 34 36 39 41 44 47 50 53 55 58 62 65 68 71 74 78 81 85 89 92 96 100 23 25 28 30 32 34 37 39 42 44 47 49 52 35 57 60 63 66 69 72 76 79 82 86 89 93 96 100 22 24 26 28 30 33 35 37 40 42 45 47 50 32 55 58 61 64 67 70 73 76 79 82 86 89 93 96 21 23 25 27 29 31 33 36 38 40 43 45 48 50 53 55 58 61 64 67 70 73 76 79 83 86 89 93 19 2.1 23 25 27 30 32 34 36 38 41 43 46 4 51 53 56 39 61 64 67 70 73 76 79 83 86 89 18 20 22 24 26 23 30 32 34 37 39 41 44 46 48 51 54 56 59 62 65 67 70 73 76 80 83 86 17 19 21 23 25 27 29 31 33 35 37 39 42 44 46 49 51 54 57 59 62 65 68 71 74 77 80 83 16 18 20 21 23 25 27 29 31 33 36 38 40 42 43 47 49 52 54 57 60 62 63 68 71 74 77 80 15 17 18 20 22 24 26 28 30 32 34 36 38 40 43 43 47 50 52 55 57 60 63 65 68 71 74 77 3—Remove back of incubator. DO NOT TOUCH ANY PART OF NOTE: The above chart is for sea level readings. A general rule of adjustment would be to add 1 to the percent value shown in the body of the chart for each 2500 feet of elevation above sea level. TURNER WHILE INCUBATOR IS PLUGGED INTO POWER. Check for loose wires, loose connection rods or jammed tray. Turns constantly when 1—Switch for Drive Motor is loose and has moved away from Swing Arm switched Cam. Loosen screws holding Switch, push switch closer to Cam and while to automatic holding it closer to Cam, tighten screws. Avoid over tightening as you *To obtain lower wet bulb readings, recommended for ratite eggs, we recommend using an inexpensive room dehumidifier, available at Sears, WW Grainger and other outlets. could break switch housing. 5