English (GB) 11.16 Pump flow (standard range) 11.18 Remote flow network output SNVT_flow_p nvoFlow; network output SNVT_flow_f nvoRemoteFlowF; This network variable output provides the flow through the pump as measured or estimated by the pump controller. This network variable output provides the flow measured somewhere in the system with a flow sensor connected to the pump. If the maximum pump flow is higher than 650 m3/h, nvoFlowF should be used as it offers an extended range. Section 5. Considerations when installing the E-pump or Hydro Multi-E provides more information on the coherence of nvoFlow and nvoFlowF. Valid range 0 to 655.34 m3/h (0.01 m3/h). Valid range -3.40282E38 to 3.40282E38 l/s. The value of 3.40282E38 l/s is not used as a physical representation of the flow, but represents invalid data and indicates that the flow cannot be measured or that no remote-flow sensor is connected. The value of 0xFFFF (655.35 m3/h) represents invalid data and indicates that the flow cannot be measured/estimated or that the flow is higher than 650 m3/h. If no remote-flow sensor is available in the system, nvoFlowF will display a value of NaN (Not a Number). When transmitted This value is transmitted immediately when it has changed more than 0.2 m3/h. When transmitted This value is transmitted immediately when it has changed significantly. The significance depends on the pump type. Product availability • For UPE Series 2000, the value must change more than 0.2 m3/h. For product availability, see overview on page 36. • For GRUNDFOS MAGNA, the value must change more than 0.3 m3/h. 11.19 Pump speed • For TPE Series 1000/2000, the value must change more than 0.5 m3/h. network output SNVT_rpm nvoSpeed; This optional network variable output provides the pump speed. Product availability Valid range For product availability, see overview on page 36. 0 to 65,534 rpm (1 rpm). 11.17 Pump flow (extended range) The value of 0xFFFF (65,535 rpm) represents invalid data and indicates that the speed cannot be measured/estimated. network output SNVT_flow_f nvoFlowF; When transmitted This network variable output provides the flow through the pump as measured or estimated by the pump. This value is transmitted immediately when it has changed more than 107 rpm. If the maximum pump flow is lower than 650 m3/h, nvoFlow should be used as it offers a higher resolution. Section 5. Considerations when installing the E-pump or Hydro Multi-E provides more information on the coherence of nvoFlow and nvoFlowF. Valid range -3.40282E38 to 3.40282E38 l/s. If no flow sensor is available in the system, nvoFlowF will display a value of NaN (Not a Number). When transmitted This value is transmitted immediately when it has changed more than 1 l/s. Product availability For product availability, see overview on page 36. 11.20 Pump override active network output SNVT_switch nvoPumpOverride; This optional network variable output provides the manual override status of the pump. This variable has the value "OVERRIDE" in the table below if the pump setpoint has been overridden by one of the variables: nviOvdSpeed, nviOvdPress or nviOvdStop. Valid range Product availability State Value Equivalent percent Requested operation For product availability, see overview on page 36. 0 0 0 NORMAL 1 200 100 OVERRIDE 0xFF n/a n/a Invalid value When transmitted This value is transmitted immediately when it has changed. Product availability For product availability, see overview on page 36. 26