Markers Three Types of Markers Three types of markers are provided for each channel. The rst is the movable marker that is displayed on the screen (as 5) when 4Marker5, 4Maker!5, 4Search5, or 4Utility5 is pressed. When a marker is turned on and no other function is active, the marker can be controlled with the knob, or the step keys. The second is the sub-markers that appear at the present marker position when a softkey in the sub-marker menu is pressed. The seven sub-markers can be displayed for each channel at same time (a total of 14). The third is the 1marker that denes a reference position of the delta mode. There three 1mode, 1marker(normal), tracking 1marker, and xed 1marker. Marker Value Markers have a sweep parameter value (the x-axis value in a Cartesian format) and a measurement value (the y-axis value in a Cartesian format). In a polar, Smith, or admittance chart format, the second part of a complex data pair is also provided as an auxiliary measurement value. The marker can be moved to any point on the trace, Its measurement and sweep parameter values are displayed at the top right corner of the graticule for each displayed channel (in units appropriate to the display format). The displayed marker measurement values are valid even when the measured data is above or below the range displayed on the graticule. When marker list is turned on, sweep parameter values and measurement values of all markers are listed on the graticule. In a polar, Smith , or admittance chart format, auxiliary measurement values of all markers are also listed. Marker Time Mode When marker time mode is turned on, the x-axis is changed to the time scale. The start point of the x-axis is 0 seconds and the stop point indicates the sweep time. The markers have a time instead of a sweep parameter value. Continuous/Discrete Mode Marker values of the network analyzer are normally continuous (that is, they are interpolated between measured points). Alternatively, they can be set to read only discrete measured points. The marker of the spectrum analyzer always reads only the discrete measured point. Marker on the Data Trace or on the Memory Trace If both data and memory are displayed, you can select which marker values apply to the data trace or the memory trace. If data or memory is displayed (not both), the marker values apply to the trace displayed. In a data math display (data+memory, data0memory, or data/memory), the marker values apply to the trace resulting from the memory math function. Analyzer Features 12-29
Related documents
Notice - Agilent Technologies
Safety Summary - Silicon Integrated Circuit Reverse Engineering
Agilent 8504B Precision Re ectometer
OWNER`S MANUAL
4395A Network/Spectrum/Impedance Analyzer Service Manual
Agilent 83480A User`s Manual
Caution 注意
Agilent / HP 83484A Manual
4396B
HP 70004A - User Guide
PERFORMANCE TEST MANUAL - Steven M. Anlage Research Page
GPIB Command Reference - Steven M. Anlage Research Page